INFANTILE HEPATIC HEMANGIOMA - DOPPLER US

被引:36
作者
PALTIEL, HJ
PATRIQUIN, HB
KELLER, MS
BABCOCK, DS
LEITHISER, RE
机构
[1] UNIV CINCINNATI, COLL MED, DEPT RADIOL, CINCINNATI, OH 45221 USA
[2] UNIV CINCINNATI, COLL MED, DEPT PEDIAT, CINCINNATI, OH 45221 USA
[3] HOP ST JUSTINE, DEPT RADIOL, MONTREAL H3T 1C5, QUEBEC, CANADA
[4] YALE UNIV, SCH MED, DEPT DIAGNOST IMAGING, NEW HAVEN, CT 06510 USA
[5] ARKANSAS CHILDRENS HOSP, DEPT RADIOL, LITTLE ROCK, AR 72202 USA
关键词
ANGIOMA; GASTROINTESTINAL TRACT; LIVER NEOPLASMS; US; ULTRASOUND; (US); DOPPLER STUDIES; IN INFANTS AND CHILDREN;
D O I
10.1148/radiology.182.3.1535887
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The duplex Doppler ultrasound (US) characteristics of 13 infantile hepatic hemangiomas were reviewed to assess the utility of these characteristics in diagnosis and follow-up. Clinical correlation was available for all children, with a histologic diagnosis established in three. A variety of tumoral flow patterns were demonstrated, including arterial and venous signals with high-frequency shifts, arteries with little systolic-diastolic flow variation, and low-frequency arterial and venous signals. Follow-up studies in 12 infants documented slower flow within the tumors; one child underwent immediate surgery without follow-up examination. The Doppler US characteristics of infantile liver hemangiomas are variable and overlap with those described in the literature for malignant tumors. Doppler US is most useful in follow-up by allowing monitoring of changes in flow within tumors after therapeutic embolization or conservative management.
引用
收藏
页码:735 / 742
页数:8
相关论文
共 23 条
[1]
HEPATOBLASTOMA - DETECTION OF TUMOR VASCULARITY WITH DUPLEX DOPPLER US [J].
BATES, SM ;
KELLER, MS ;
RAMOS, IM ;
CARTER, D ;
TAYLOR, KJW .
RADIOLOGY, 1990, 176 (02) :505-507
[2]
ARTERIOPORTAL COMMUNICATIONS - OBSERVATIONS AND HYPOTHESES CONCERNING TRANS-SINUSOIDAL AND TRANS-VASAL TYPES [J].
BOOKSTEIN, JJ ;
CHO, KJ ;
DAVIS, GB ;
DAIL, D .
RADIOLOGY, 1982, 142 (03) :581-590
[3]
BURNS PN, 1983, J PHYSIOL-LONDON, V342, pP12
[4]
BURROWS PE, 1989, 32ND ANN M SOC PED R
[5]
DACHMAN AH, 1983, AM J ROENTGENOL, V140, P1091, DOI 10.2214/ajr.140.6.1091
[6]
DEHNER LP, 1971, ARCH PATHOL, V92, P101
[7]
FELLOWS KE, 1990, RADIOLOGY, V177, P235
[8]
RENAL MASSES - CHARACTERIZATION WITH DOPPLER US [J].
KIER, R ;
TAYLOR, KJW ;
FEYOCK, AL ;
RAMOS, IM .
RADIOLOGY, 1990, 176 (03) :703-707
[9]
ASSURANCE OF CONSISTENT PEAK-VELOCITY MEASUREMENTS WITH A VARIETY OF DUPLEX DOPPLER INSTRUMENTS [J].
KIMMESMITH, C ;
HUSSAIN, R ;
DUERINCKX, A ;
TESSLER, F ;
GRANT, E .
RADIOLOGY, 1990, 177 (01) :265-272
[10]
KLEIN MA, 1990, J ULTRAS MED, V9, P619