As radiometric lamp standards improve, the need to set lamp current to specific values becomes more important. Commercially available power supplies typically provide 12 bit internal digital-to-analog logic which permits current control with a relative expanded uncertainty of about 1 part in 4096, corresponding to an expanded uncertainty of the current of about 2 mA at 8 A (in this paper, expanded uncertainties are given as 2 standard deviations). For an FEL-type standard spectral irradiance lamp, this corresponds to a spectral irradiance difference of 0.12% at 655 nm. We have developed a technique using 16 bit digital-to-analog conversion which permits current control with a relative expanded uncertainty of about 1 part in 65536, corresponding to an expanded uncertainty of the current of about 0.1 mA at 8 A. This corresponds to a spectral irradiance difference of approximately 0.006% for an FEL lamp at 655 nm. We describe the technique used to achieve this improvement and we show data from a lamp demonstrating the effect of the improvement. We also describe the limitation provided by the uncertainty of the resistance of the current measuring shunt.