High sensitivity, high spatial resolution and multielement determination are important properties of PIXE facilitating the elemental analysis of biomedical material. The possibility of simultaneous use of nuclear ion-beam techniques is also essential. In order to fully exploit the technique, the samples must be carefully prepared, the correct parameters must be chosen for target irradiation and the results must be carefully checked and interpreted. Biological/medical specimens have to be collected and processed in a suitable way in order to maintain the elemental information until irradiation without becoming contaminated. The mode of ion-beam irradiation (in or ex vacuo, macro- or microbeam) will depend on sample size, scientific questions to be answered and the risk of target degradation. Quality control and the use of reference material is an essential ingredient in all forms of analytical chemistry and should be used more frequently in PIXE analysis. © 1990.
引用
收藏
页码:183 / 190
页数:8
相关论文
共 48 条
[1]   PIXE ANALYSIS OF MINERAL MATTER IN THIN-SECTIONS OF HUMAN-LUNG [J].
ANNEGARN, HJ ;
PILLAY, AE ;
DAVIES, JCA ;
FAURE, D ;
SELLSCHOP, JPF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1988, 35 (3-4) :415-419
[2]  
CAMPBELL JL, 1989, SCANNING MICROSCOPY, V3, P449
[3]   AN INTERCOMPARISON OF SPECTRAL DATA-PROCESSING TECHNIQUES IN PIXE [J].
CAMPBELL, JL ;
MAENHAUT, W ;
BOMBELKA, E ;
CLAYTON, E ;
MALMQVIST, K ;
MAXWELL, JA ;
PALLON, J ;
VANDENHAUTE, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1986, 14 (02) :204-220
[4]   X-RAY SPECTROMETERS FOR PIXE [J].
CAMPBELL, JL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 49 (1-4) :115-125
[5]  
CHAUDHRI MA, 1981, NUCL INSTRUM METHODS, V181, P327, DOI 10.1016/0029-554X(81)90631-5
[6]   TEMPERATURE ESTIMATION OF ORGANIC FOIL FOR PARTICLE BEAMS [J].
CHOLEWA, M ;
LEGGE, GJF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 40-1 :651-654
[8]   APPLICATION OF PIXE ANALYSIS TO THE STUDY OF THE REGIONAL DISTRIBUTION OF TRACE-ELEMENTS IN NORMAL HUMAN-BRAIN [J].
DUFLOU, H ;
MAENHAUT, W ;
DEREUCK, J .
BIOLOGICAL TRACE ELEMENT RESEARCH, 1987, 13 :1-17
[9]   ANGULAR-DISTRIBUTION OF PARTICLE-INDUCED X-RAY-EMISSION [J].
FOLKMANN, F ;
CRAMON, KM ;
HERTEL, N .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1984, 3 (1-3) :11-15
[10]   APPLICATION OF PIXE TO TRACE-ELEMENT ANALYSIS IN BIOLOGICAL TISSUES [J].
HASSELMANN, I ;
KOENIG, W ;
RICHTER, FW ;
STEINER, U ;
WATJEN, U ;
BODE, JC ;
OHTA, W .
NUCLEAR INSTRUMENTS & METHODS, 1977, 142 (1-2) :163-169