IN-VITRO FATIGUE BEHAVIOR OF RESTORATIVE COMPOSITES AND GLASS IONOMERS

被引:60
作者
BRAEM, MJA [1 ]
LAMBRECHTS, P [1 ]
GLADYS, S [1 ]
VANHERLE, G [1 ]
机构
[1] KATHOLIEKE UNIV LEUVEN,SCH DENT,DEPT OPERAT DENT,B-3001 LOUVAIN,BELGIUM
关键词
D O I
10.1016/0109-5641(95)80049-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. This in vitro study was conducted to investigate the fatigue behavior of several dental restoratives, including composites, glass ionomers and a resin-reinforced glass ionomer. Methods. Fatigue was imposed under a reverse stress-controlled regimen, following a staircase approach. Samples were stored and tested under both dry and wet conditions. The following parameters were measured and analyzed:Young's modulus, restrained fracture strength, and flexural fatigue limit. Results. As a general trend, all products showed a decrease in Young's modulus following water sorption. For all products except the resin-reinforced glass ionomer, the same trend was seen in the restrained fracture strength. This is, however, no longer valid for the flexural fatigue limit: the trend is steady-stale for the glass ionomers, status quo for the resin-reinforced glass ionomer, and all composites tested show a decrease. Significance, The diversity in structure of both composites and glass ionomers does not allow findings for one product to be extrapolated to other similar products.
引用
收藏
页码:137 / 141
页数:5
相关论文
共 12 条
[1]   INVIVO EVALUATION OF 4 POSTERIOR COMPOSITES - QUANTITATIVE WEAR MEASUREMENTS AND CLINICAL BEHAVIOR [J].
BRAEM, M ;
LAMBRECHTS, P ;
VANDOREN, V ;
VANHERLE, G .
DENTAL MATERIALS, 1986, 2 (03) :106-113
[2]   IN-VITRO FLEXURAL FATIGUE LIMITS OF DENTAL COMPOSITES [J].
BRAEM, MJA ;
DAVIDSON, CL ;
LAMBRECHTS, P ;
VANHERLE, G .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (12) :1397-1402
[3]  
DAVIDSON CL, 1994, J DENT RES, V73, P181
[4]   FRACTURE PROPERTIES OF COMPOSITE AND GLASS IONOMER DENTAL RESTORATIVE MATERIALS [J].
GOLDMAN, M .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1985, 19 (07) :771-783
[5]  
HAHNEL L, 1986, BMFTDFVLR01ZA1007 FR
[6]   STRUCTURAL EVIDENCES OF THE MICROFILLED COMPOSITES [J].
LAMBRECHTS, P ;
VANHERLE, G .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1983, 17 (02) :249-260
[7]  
LAMBRECHTS P, 1987, OPER DENT, V12, P53
[8]   FATIGUE AND WEAR OF DENTAL MATERIALS [J].
REID, CN ;
FISHER, J ;
JACOBSEN, PH .
JOURNAL OF DENTISTRY, 1990, 18 (04) :209-215
[9]   DEGRADATION OF GLASS FILLER IN EXPERIMENTAL COMPOSITES [J].
SODERHOLM, KJ .
JOURNAL OF DENTAL RESEARCH, 1981, 60 (11) :1867-1875
[10]   CORRELATION BETWEEN FRACTURE PROPERTIES AND CLINICAL-PERFORMANCE OF COMPOSITE RESINS IN CLASS-IV CAVITIES [J].
TYAS, MJ .
AUSTRALIAN DENTAL JOURNAL, 1990, 35 (01) :46-49