THE HOFFER-Q FORMULA - A COMPARISON OF THEORETIC AND REGRESSION FORMULAS

被引:448
作者
HOFFER, KJ
机构
关键词
ANTERIOR CHAMBER DEPTH; AXIAL LENGTH; HOFFER Q FORMULA; HOLLADAY FORMULA; INTRAOCULAR LENS POWER CALCULATION; INTRAOCULAR LENS POWER ERROR; REGRESSION FORMULA; SRK FORMULAS; ULTRASOUND;
D O I
10.1016/S0886-3350(13)80338-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A new formula, the Hoffer Q, was developed to predict the pseudophakic anterior chamber depth (ACD) for theoretic intraocular lens (lOL) power formulas. It relies on a personalized ACD, axial length, and corneal curvature. In 180 eyes, the Q formula proved more accurate than those using a constant ACD (P <.0001) and equal (P =.63) to those using the actual postoperative measured ACD (which is not possible clinically). In 450 eyes of one style lOL implanted by one surgeon, the Hoffer Q formula was equal to the Holladay (P =.65) and SRK/T (P =.63) and more accurate than the SRK (P <.0001) and SRK II (P =.004) regression formulas using optimized personalization constants. The Hoffer Q formula may be clinically more accurate than the Holladay and SRK/T formulas in eyes shorter than 22.0 mm. Even the original nonpersonalized constant ACD Hoffer formula compared with SRK I (using the most valid possible optimized personal A-constant) has a better mean absolute error (0.56 versus 0.59) and a significantly better range of IOL prediction error (3.44 diopters [D] versus 7.31 D). The range of error of the Hoffer Q formula (3.59 D) was half that of SRK I (7.31 D). The highest lOL power errors in the 450 eyes were in the SRK II (3.14 D) and SRK I (6.14 D); the power error was 2.08 D using the Hoffer Q formula. The series using overall personalized ACD was more accurate than using an axial length subgroup personalized ACD in each axial length subgroup. The results strongly support replacing regression formulas with third-generation personalized theoretic formulas and carefully evaluating the Holladay, SRK/T, and Hoffer Q formulas.
引用
收藏
页码:700 / 712
页数:13
相关论文
共 25 条
[1]  
Learning DV, Practice styles and pReferences of ASCRS members-1989 survey, J Cataract Refract Surg, 16, pp. 624-632, (1990)
[2]  
Fedorov SN, Kolinko AI, Estimation of optical power of the intraocular lens, Vestn Oftalmol, 80, 4, pp. 27-31, (1967)
[3]  
Colenbrander MC, Calculation of the power of an iris clip lens for distant vision, Br J Ophthalmol, 57, pp. 735-740, (1973)
[4]  
Hoffer KJ, Mathematics and computers in intraocular lens calculation, American Intra-Ocular Implant Society Newsletter, 1, 1, pp. 4-5, (1975)
[5]  
Hoffer KJ, Intraocular lens calculation: The problem of the short eye, Ophthalmic Surg, 12, pp. 269-272, (1981)
[6]  
van der Heijde GL, A nomogram for calculating the power of the prepupillary lens in the aphakic eye, Bibliotheca Ophthalmol, 83, pp. 273-275, (1975)
[7]  
Thijssen JM, The emmetropic and the iseikonic implant lens: computer calculation of the refractive power and its accuracy, Ophthalmologica, 171, pp. 467-486, (1975)
[8]  
Binkhorst RD, The optical design of intraocular lens implants, Ophthalmic Surg, 6, 3, pp. 17-31, (1975)
[9]  
Gills JP, Minimizing postoperative refractive error, Contact Intraocular Lens Med J, 6, pp. 56-59, (1980)
[10]  
Sanders DR, Kraff MC, Improvement of intraocular lens power calculation using empirical data, Am Intra-Ocular Implant Soc J, 6, pp. 263-267, (1980)