1ST-PASS EVALUATION OF RENAL PERFUSION WITH TURBOFLASH MR-IMAGING AND SUPERPARAMAGNETIC IRON-OXIDE PARTICLES

被引:21
作者
TRILLAUD, H [1 ]
GRENIER, N [1 ]
DEGREZE, P [1 ]
LOUAIL, C [1 ]
CHAMBON, C [1 ]
FRANCONI, JM [1 ]
机构
[1] HOP PELLEGRIN,DEPT RADIOL,PL AMELIE RABA LEON,F-33076 BORDEAUX,FRANCE
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1993年 / 3卷 / 01期
关键词
CONTRAST ENHANCEMENT; CONTRAST MEDIA; HYDRONEPHROSIS; IRON; KIDNEY; BLOOD SUPPLY; MR; PERFUSION STUDIES; RENAL ARTERIES; STENOSIS OR OBSTRUCTION; VASCULAR STUDIES;
D O I
10.1002/jmri.1880030115
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
First-pass intrarenal hemodynamics were studied with superparamagnetic iron oxide particles and a T2-weighted TurboFLASH (fast low-angle shot) magnetic resonance (MR) imaging sequence. Four groups of five rabbits each were imaged after bolus injection of 40, 100, 140, and 200 mumol/kg iron, respectively. Images were acquired every 1.2 seconds, with an acquisition time of 700 msec. The signal intensity was measured in the cortex, outer medulla, inner medulla, and globally. In preliminary pathologic applications, two rabbits were imaged after ligation of the lumbar ureter and two after embolization of the renal artery. The reproducibility of the normal dynamics was evaluated with a cross-correlation test. On the images, the intravascular progression of the iron particles could be visualized within the cortex and the two compartments of the medulla in all cases. The maximal reduction in signal intensity in the cortex and medulla increased with the dose. The relationship between signal intensity decrease and dose was not linear, and the reproducibility of the signal intensity versus time plots was acceptable only at the 140 and 200 mumol/kg doses. The decrease in signal intensity was reduced and delayed in the embolized and hydronephrotic kidneys.
引用
收藏
页码:83 / 91
页数:9
相关论文
共 23 条
[1]  
Knox FG, Ritman EL, Romero JC, Intrarenal distribution of blood flow: evolution of a new approach to measurement, Kidney Int, 25, pp. 473-479, (1984)
[2]  
Jaschke WR, Gould RG, Cogan MG, Sievers R, Lipton MJ, Cine‐CT measurement of cortical renal blood flow, J Com‐put Assist Tomogr, 11, pp. 779-784, (1987)
[3]  
Jaschke WR, Sievers R, Lipton MJ, Cogan MG, Cine‐CT assessment of regional renal blood flow, Acta Radiol, 31, pp. 77-81, (1989)
[4]  
Gur D, Yonas H, Wolfson SK, Et al., Xenon/CT blood flow mapping of the kidney and liver, J Comput Assist Tomogr, 8, pp. 1124-1127, (1984)
[5]  
Powers TA, Lorenz CH, Holburn GE, Price RR, Renal artery stenosis: in vivo perfusion MR imaging, Radiology, 178, pp. 543-548, (1991)
[6]  
Rosen BR, Belliveau JW, Vevea JM, Brady TJ, Perfusion imaging with NMR contrast agents, Magn Reson Med, 14, pp. 249-265, (1990)
[7]  
Gore JC, Majumdar S, Measurement of tissue blood flow using intravascular relaxation agents and magnetic resonance imaging, Magn Reson Med, 14, pp. 242-248, (1990)
[8]  
Haase A, Snapshot FLASH MRI: applications to T1, T2, and chemical‐shift imaging, Magn Reson Med, 13, pp. 77-89, (1990)
[9]  
Carvlin MJ, Arger PH, Kundel HL, Et al., Use of GD‐DTPA and fast gradient‐echo and spin‐echo MR imaging to demonstrate renal function in the rabbit, Radiology, 170, pp. 705-711, (1989)
[10]  
Choyke PL, Frank JA, Girton ME, Et al., Dynamic GD‐DTPA‐enhanced MR imaging of the kidney: experimental results, Radiology, 170, pp. 713-720, (1989)