DETERMINATION OF SULFUR AMINO-ACIDS BY GAS-CHROMATOGRAPHY WITH FLAME PHOTOMETRIC DETECTION

被引:14
作者
KATAOKA, H
TANAKA, H
FUJIMOTO, A
NOGUCHI, I
MAKITA, M
机构
[1] Faculty of Pharmaceutical Sciences, Okayama University, Tsushima
关键词
D O I
10.1002/bmc.1130080305
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A selective and sensitive method has been developed for the determination of sulphur amino acids by gas chromatography (GC). Sulphur amino acids were converted into their N(S)-isopropoxycarbonyl methyl ester derivatives and measured by GC with flame photometric detection using a DB-17 capillary column. The derivatives were sufficiently volatile and stable to give single symmetrical peaks. The detection limits of sulphur amino acids were ca. 0.5-1 pmol per injection, and the calibration curves were linear in the range 0.5-10 nmol for each sulphur amino acid. This method was successfully applied to small urine samples without prior cleanup, and sulphur amino acids in these samples could be analysed without any influence from coexisting substances. Overall recoveries of sulphur amino acids added to urine samples were 85-113%. The analytical results of free sulphur amino acid contents in urine samples of normal subjects are presented.
引用
收藏
页码:119 / 124
页数:6
相关论文
共 35 条
[1]   DETERMINATION OF HOMOCYSTEINE IN PLASMA BY ION-EXCHANGE CHROMATOGRAPHY [J].
ANDERSSON, A ;
BRATTSTROM, L ;
ISAKSSON, A ;
ISRAELSSON, B ;
HULTBERG, B .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1989, 49 (05) :445-449
[2]  
ANDERSSON A, 1993, CLIN CHEM, V39, P1590
[3]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF URINARY CYSTEINE AND CYSTINE [J].
BIRWE, H ;
HESSE, A .
CLINICA CHIMICA ACTA, 1991, 199 (01) :33-42
[4]   SEPARATION BY GAS-LIQUID CHROMATOGRAPHY OF SILYLATED DERIVATIVES OF SOME SULFO- AND SELENOAMINO ACIDS AND THEIR OXIDATION PRODUCTS [J].
CALDWELL, KA ;
TAPPEL, AL .
JOURNAL OF CHROMATOGRAPHY, 1968, 32 (04) :635-&
[5]   BIOCHEMISTRY OF SULFUR-CONTAINING AMINO-ACIDS [J].
COOPER, AJL .
ANNUAL REVIEW OF BIOCHEMISTRY, 1983, 52 :187-222
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF CYSTATHIONINE, LANTHIONINE AND AMINOETHYLCYSTEINE USING ORTHO-PHTHALDIALDEHYDE PRECOLUMN DERIVATIZATION [J].
COSTA, M ;
PECCI, L ;
PENSA, B ;
FONTANA, M ;
CAVALLINI, D .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 490 (02) :404-410
[7]   DETERMINATION OF S-CARBOXYMETHYLCYSTEINE IN SERUM BY REVERSED-PHASE ION-PAIR LIQUID-CHROMATOGRAPHY WITH COLUMN SWITCHING FOLLOWING PRE-COLUMN DERIVATIZATION WITH ORTHO-PHTHALALDEHYDE [J].
DESCHUTTER, JA ;
VANDERWEKEN, G ;
VANDENBOSSCHE, W ;
DEMOERLOOSE, P .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 428 (02) :301-310
[8]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD WITH FLUORESCENCE DETECTION FOR THE DETERMINATION OF TOTAL HOMOCYST(E)INE IN PLASMA [J].
FERMO, I ;
ARCELLONI, C ;
DEVECCHI, E ;
VIGANO, S ;
PARONI, R .
JOURNAL OF CHROMATOGRAPHY, 1992, 593 (1-2) :171-176
[9]  
FINKELSTEIN JD, 1975, METABOLIC PATHWAYS, V7, P547
[10]  
FISKERSTRAND T, 1993, CLIN CHEM, V39, P263