UPPER ABDOMINAL PHASE-CONTRAST MR-ANGIOGRAPHY - COMPARISON OF CINE AND NON-CINE TECHNIQUES

被引:13
作者
BURKART, DJ
JOHNSON, CD
机构
[1] Department of Diagnostic Radiology, Mayo Clinic and Foundation, Rochester, MN 55905
关键词
ABDOMEN; MR; MAGNETIC RESONANCE (MR); PHASE IMAGING; TECHNOLOGY; VASCULAR STUDIES;
D O I
10.1148/radiology.195.1.7892447
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate image quality, vessel conspicuity, and signal-to-noise ratio (S/N) of four two-dimensional magnetic resonance (MR) phase-contrast techniques: cine phase-contrast with respiratory compensation (CPC-R), cine phase-contrast without respiratory compensation (CPC), phase-contrast with two signals acquired (PC-2), and phase-contrast with eight signals acquired (PC-8). MATERIALS AND METHODS: MR angiographic images of the portal vein were obtained in 14 patients. RESULTS: Overall image quality was rated excellent in 10 of 14 patients (CPC-R), in one of 14 patients (CPC), in none of 14 patients (PC-2), and in one of 14 patients (PC-8). Views of 10 upper abdominal vessels were evaluated with each technique. The mean (+/- standard deviation) number of well-imaged vessels was 6 +/- 2 (CPC-R), 3 +/- 2 (CPC), 2 +/- 2 (PC-2), and 3 +/- 2 (PC-8). CPC-R images were significantly better in overall image quality and number of vessels seen (P <.01). Mean S/Ns were 10.8 +/- 3.4 (CPC-R), 6.8 +/- 2.7 (CPC), 4.5 +/- 1.7 (PC-2), and 6.4 +/- 2.1 (PC-8). S/N with CPC-R was significantly greater than with CPC, PC-2 or PC-8. CONCLUSION: CPC-R provided consistently higher quality angiographic images than were obtained with the other sequences studied.
引用
收藏
页码:101 / 105
页数:5
相关论文
共 10 条
  • [1] COMPARISON OF PHASE-DIFFERENCE AND COMPLEX-DIFFERENCE PROCESSING IN PHASE-CONTRAST MR ANGIOGRAPHY
    BERNSTEIN, MA
    IKEZAKI, Y
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (06): : 725 - 729
  • [2] BERNSTEIN MA, 1994, ANN M SOC MAGNETIC S, pS23
  • [3] PHASE-CONTRAST CINE MR ANGIOGRAPHY IN CHRONIC LIVER-DISEASE
    BURKART, DJ
    JOHNSON, CD
    MORTON, MJ
    EHMAN, RL
    [J]. RADIOLOGY, 1993, 187 (02) : 407 - 412
  • [4] MAGNETIC-RESONANCE ANGIOGRAPHY
    DUMOULIN, CL
    HART, HR
    [J]. RADIOLOGY, 1986, 161 (03) : 717 - 720
  • [5] FREDRICKSON JO, 1992, RADIOLOGY, V185, P303
  • [6] BLOOD-FLOW IMAGING BY CINE MAGNETIC-RESONANCE
    NAYLER, GL
    FIRMIN, DN
    LONGMORE, DB
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) : 715 - 722
  • [7] PELC N J, 1991, Magnetic Resonance Quarterly, V7, P229
  • [8] ENCODING STRATEGIES FOR 3-DIRECTION PHASE-CONTRAST MR IMAGING OF FLOW
    PELC, NJ
    BERNSTEIN, MA
    SHIMAKAWA, A
    GLOVER, GH
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (04): : 405 - 413
  • [9] PIKE GB, 1993, RADIOLOGY P, V189, P291
  • [10] PERIPHERAL VASCULAR AND ABDOMINAL APPLICATIONS OF MR FLOW IMAGING TECHNIQUES
    STEINBERG, FL
    YUCEL, EK
    DUMOULIN, CL
    SOUZA, SP
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) : 315 - 320