RADIOLOGICAL AND HISTOLOGICAL STUDY OF ASEPTIC LOOSENING USING A CEMENTED TIBIAL HEMIARTHROPLASTY IN THE RABBIT KNEE

被引:12
作者
GOODMAN, SB
MAGEE, FP
FORNASIER, VL
机构
[1] IATROMED INC, PHOENIX, AZ USA
[2] HARRINGTON ARTHRITIS RES CTR, PHOENIX, AZ USA
[3] UNIV TORONTO, PRINCESS MARGARET HOSP, BONE & JOINT RES LAB, TORONTO M4X 1K9, ONTARIO, CANADA
[4] UNIV TORONTO, WELLESLEY HOSP, TORONTO M4Y 1J3, ONTARIO, CANADA
关键词
HEMIARTHROPLASTY; PROSTHESIS FIT; PMMA;
D O I
10.1016/0142-9612(93)90241-S
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fourteen mature New Zealand white female rabbits had a unilateral cemented, stemmed, titanium, condylar-type tibial hemiarthroplasty, using an anteromedial arthrotomy of the right knee. The articular cartilage and minimal bone were resected. There were two prosthetic groups of seven animals each: a well-fixed, non-loose group and a loose group. In the non-loose group, the implant was inserted into the cement bed and axially compressed until the PMMA had cured. In the loose group, the same volume of cement was allowed to cure on the implant ex vivo; the prosthesis was then implanted to ensure that it was loose fitting. Radiographs were performed at zero and 3 months and graded for new lucent lines. Histological analysis was performed using undecalcified coronal sections, surface stained with toluidine blue with the prosthesis in situ, and the cement mantle preserved. Back-scattered electron microscopy was also performed. The mean cumulative grading of new lucent lines was 0.3 +/- 0.1 for the non-loose group and 2.2 +/- 0.4 for the loose group (P < 0.005). Non-loose prostheses were surrounded by a thin fibrous membrane or bone. Loose prostheses were surrounded by a thicker, fibrous tissue layer, containing histiocytes and giant cells which were more prevalent around cement particles, especially near the prosthetic tip. These findings parallel the histology found at cemented prosthetic interfaces in humans. The results of this study suggest that the fibrohistiocytic membrane commonly found around loose cemented implants may be the result of, rather than the cause of, the loosening process.
引用
收藏
页码:522 / 528
页数:7
相关论文
共 53 条
  • [1] AHMED A M, 1984, Journal of Orthopaedic Research, V2, P105, DOI 10.1002/jor.1100020201
  • [2] AMSTUTZ HC, 1982, CLIN ORTHOP RELAT R, V170, P21
  • [3] APPEL AM, 1988, T ORTHOP RES SOC, V13, P362
  • [4] AYERS DC, 1989, 35TH T ANN ORTH RES, V14, P227
  • [5] A STUDY OF IMPLANT FAILURE IN THE WAGNER RESURFACING ARTHROPLASTY
    BELL, RS
    SCHATZKER, J
    FORNASIER, VL
    GOODMAN, SB
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (08) : 1165 - 1175
  • [6] BULLOUGH PG, 1973, HIP, P80
  • [7] CHARNLEY J, 1970, Journal of Bone and Joint Surgery British Volume, V52, P340
  • [8] Charnley J., 1979, LOW FRICTION ARTHROP
  • [9] CHARACTERIZATION OF TISSUE FROM THE BONE-POLYMETHYLMETHACRYLATE INTERFACE IN A RAT EXPERIMENTAL-MODEL - DEMONSTRATION OF COLLAGEN-DEGRADING ACTIVITY AND BONE-RESORBING POTENTIAL
    COE, MR
    FECHNER, RE
    JEFFREY, JJ
    BALIAN, G
    WHITEHILL, R
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (06) : 863 - 874
  • [10] DELEE JG, 1976, CLIN ORTHOP RELAT R, P20