DIAGNOSTIC-ACCURACY AND THERAPEUTIC IMPACT OF TRANSTHORACIC AND TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN MECHANICALLY VENTILATED PATIENTS IN THE ICU

被引:151
作者
VIGNON, P
MENTEC, H
TERRE, S
GASTINNE, H
GUERET, P
LEMAIRE, F
机构
[1] DUPUYTREN HOSP,DEPT CARDIOL,LIMOGES,FRANCE
[2] HOP HENRI MONDOR,DEPT MED INTERNS CARE,CRETEIL,FRANCE
关键词
ECHOCARDIOGRAPHY; INTENSIVE CARE UNIT; MECHANICAL VENTILATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;
D O I
10.1378/chest.106.6.1829
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objectives: To assess the respective diagnostic accuracy of transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) and their therapeutic implications in mechanically ventilated patients, in the intensive care unit (ICU). Design: A prospective study. Settings: Intensive care units of two tertiary referral teaching hospitals. Patients: One hundred eleven ICU patients (81 men and 30 women; mean age 57+/-16 years). Fifty-seven percent were hospitalized for medical illnesses, 16.5 percent after thoracic surgery, 10.5 percent after other surgery, and 16.0 percent for multiple trauma. Their Simplified Acute Physiologic Score was 16+/-5. Interventions: The echocardiograms were performed in order to solve well-defined clinical problems. TTE was the first step of the procedure and TEE was performed only when (1) TTE did not solve the clinical problems, and (2) TTE yielded unsuspected findings requiring TEE. During each echocardiographic study, the following were noted: ventilatory mode, clinical problems, imaging quality, results, consequence on acute care, duration of the procedure, and potential complications of TEE, Diagnostic accuracy was defined as the proportion of solved problems, and therapeutic impact was defined as changes on acute care that resulted directly from the procedure. Measurements and Results: One hundred twenty-eight consecutive TTE and 96 TEE were performed. TTE solved 60 of 158 clinical problems (38 percent), whether positive end-expiratory pressure (>4 cm H2O) was present or not(28 of 74 vs 32 of 84: p>0.50). TTE allowed evaluation of left ventricular function in 77 percent of cases and pericardial effusion in every case, but it did not solve most of the other clinical problems. Indeed, the diagnostic accuracy of TEE was markedly superior (95/98 vs 60/158: p<0.001), but TEE required a physician's presence longer (43+/-17 min vs 27+/-12 min: p<0.001). When TTE and TEE were scheduled (n=96), TEE yielded an additional diagnosis or excluded with more certitude a suspected diagnosis, except in two cases. TEE had a therapeutic impact more frequently than TTE (35/96 vs 20/128: p<0.001). Cardiovascular surgery was prompted by echocardiographic findings in ten patients. TEE was well tolerated in all patients; there were no complications. Conclusions: TEE is a valuable well-tolerated imaging technique in mechanically ventilated patients. For the assessment of left ventricular systolic function and pericardial effusion; however, TTE continues to be an excellent diagnostic tool, even when positive end-expiratory pressure is present. Both TTE and TEE have a therapeutic impact in approximately 25 percent of cases.
引用
收藏
页码:1829 / 1834
页数:6
相关论文
共 33 条
[1]  
ANSARI A, 1993, PROG CARDIOVASC DIS, V5, P349
[2]   TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN PATIENTS WITH MECHANICAL CIRCULATORY ASSISTANCE [J].
BRACK, M ;
OLSON, JD ;
PEDERSEN, WR ;
GOLDENBERG, IF ;
GOBEL, FL ;
PRITZKER, MR ;
EMERY, RW ;
LANGE, HW .
ANNALS OF THORACIC SURGERY, 1991, 52 (06) :1306-1309
[3]   2-DIMENSIONAL ECHOCARDIOGRAPHICALLY GUIDED PERICARDIOCENTESIS - EXPERIENCE IN 117 CONSECUTIVE PATIENTS [J].
CALLAHAN, JA ;
SEWARD, JB ;
NISHIMURA, RA ;
MILLER, FA ;
REEDER, GS ;
SHUB, C ;
CALLAHAN, MJ ;
SCATTENBERG, TT ;
TAJIK, AJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (04) :476-479
[4]   TRANS-ESOPHAGEAL ECHOCARDIOGRAPHY FOR ASSESSING CAUSE OF HYPOTENSION AFTER CARDIAC-SURGERY [J].
CHAN, KL ;
BLAKLEY, M ;
ANDREWS, J ;
BARRIE, M .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 62 (16) :1142-1143
[5]  
CHANDRASEKARAN K, 1989, Journal of the American College of Cardiology, V13, p51A
[6]  
CHILLO F, 1993, ARCH MAL COEUR, V86, P672
[7]   SAFETY OF TRANSESOPHAGEAL ECHOCARDIOGRAPHY - A MULTICENTER SURVEY OF 10,419 EXAMINATIONS [J].
DANIEL, WG ;
ERBEL, R ;
KASPER, W ;
VISSER, CA ;
ENGBERDING, R ;
SUTHERLAND, GR ;
GRUBE, E ;
HANRATH, P ;
MAISCH, B ;
DENNIG, K ;
SCHARTL, M ;
KREMER, P ;
ANGERMANN, C ;
ILICETO, S ;
CURTIUS, JM ;
MUGGE, A .
CIRCULATION, 1991, 83 (03) :817-821
[8]   INITIAL EXPERIENCE AND POTENTIAL APPLICATIONS OF MULTIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHY [J].
DANIEL, WG ;
PEARLMAN, AS ;
HAUSMANN, D ;
BARGHEER, K ;
MUGGE, A ;
NONNASTDANIEL, B ;
LICHTLEN, PR .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (04) :358-361
[9]   IMPROVEMENT IN THE DIAGNOSIS OF ABSCESSES ASSOCIATED WITH ENDOCARDITIS BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY [J].
DANIEL, WG ;
MUGGE, A ;
MARTIN, RP ;
LINDERT, O ;
HAUSMANN, D ;
NONNASTDANIEL, B ;
LAAS, J ;
LICHTLEN, PR .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (12) :795-800
[10]  
ERBEL R, 1988, EUR HEART J, V9, P43