TISSUE CHARACTERIZATION USING INTELLIGENT ADAPTIVE FILTER LN THE DIAGNOSIS OF DIFFUSE AND FOCAL LIVER-DISEASE

被引:17
作者
BLECK, JS [1 ]
GEBEL, M [1 ]
HEBEL, R [1 ]
WAGNER, S [1 ]
SCHMIDT, K [1 ]
KRUIP, S [1 ]
WESTHOFFBLECK, H [1 ]
WOLF, M [1 ]
THIESEMANN, C [1 ]
MANNS, R [1 ]
机构
[1] SIEMENS AG,MED ENGN GRP,ERLANGEN,GERMANY
关键词
IMAGES PROCESSING; LIVER; ULTRASOUND TECHNOLOGY; SPECKLE; ULTRASOUND TISSUE CHARACTERIZATION;
D O I
10.1016/0301-5629(94)90088-4
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In ultrasonic imaging an adaptive two-dimensional filter (ATDF) can suppress randomly generated speckle using the ratio of the local variance to the local mean as the speckle recognition feature (R). The degree of smoothing depends on the difference between the recognition feature in the region to be filtered and the selected reference tissue. We have investigated the clinical application of ATDF for ultrasound B-mode images of liver abnormalities. Using the R values of normal liver as reference values, the ATDF images were displayed. Normal livers (n = 17, R = 2.19 +/- 0.14 M +/- SEM), fatty livers (N = 16, R = 1.89 +/- 0.15) and those with acute hepatitis (N = 10, R = 2.25 +/- 0.18) appeared smooth after application of the adaptive filter, but those diseases with higher R values, such as chronic hepatitis (N = 10, R = 3.04 +/- 0.30), cirrhosis (n = 16, R = 4.44 +/- 0.30 +/- metastases (N = 16, R = 6.43 +/- 0.53) and hepatocellular carcinomas (N = 8, R = 7.92 +/- 0.85), were largely unsmoothed. In conclusion, ATDF allows differentiation of some forms of liver disease and may be helpful in the detection of microfocal echogenic textural lesions.
引用
收藏
页码:521 / 528
页数:8
相关论文
共 14 条
  • [1] ADAPTIVE FILTERING FOR REDUCTION OF SPECKLE IN ULTRASONIC PULSE-ECHO IMAGES
    BAMBER, JC
    DAFT, C
    [J]. ULTRASONICS, 1986, 24 (01) : 41 - 44
  • [2] BAMBER JC, 1992, ACOUST IMAG, V19, P447
  • [3] BAMBER JC, 1987, SPIE P, V768, P120
  • [4] BEKESY GV, 1967, J GEN PHYSIOL, V50, P519
  • [5] VISUAL IMPACT OF ADAPTIVE SPECKLE REDUCTION ON US B-MODE IMAGES
    CRAWFORD, DC
    COSGROVE, DO
    TOHNO, E
    SVENSSON, WE
    ALMURRANI, B
    BELL, DS
    STEPNIEWSKA, K
    BAMBER, JC
    [J]. RADIOLOGY, 1992, 183 (02) : 555 - 561
  • [6] COMPENSATION FOR THE SIGNAL-PROCESSING CHARACTERISTICS OF ULTRASOUND B-MODE SCANNERS IN ADAPTIVE SPECKLE REDUCTION
    CRAWFORD, DC
    BELL, DS
    BAMBER, JC
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (06) : 469 - 485
  • [7] ERNST H, 1991, EINFUHRUNG DIGITALE, P53
  • [8] ULTRASONIC CHARACTERIZATION OF TISSUE STRUCTURE IN THE INVIVO HUMAN-LIVER AND SPLEEN
    FELLINGHAM, LL
    SOMMER, FG
    [J]. IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1984, 31 (04): : 418 - 428
  • [9] JACOBS EGMP, 1992, ACOUST IMAG, V19, P493
  • [10] LOWE H, 1988, SPIE P, V914, P40