IMPROVED DUAL CHAMBER PACING MODE IN PAROXYSMAL ATRIOVENTRICULAR-CONDUCTION DISORDERS

被引:9
作者
GIRODO, S
RITTER, P
PIOGER, G
LAMAISON, D
MALHERBE, O
机构
[1] ALLERAY CLIN,PARIS,FRANCE
[2] CHU ST JACQUES,CLERMONT FERRAND,FRANCE
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1990年 / 13卷 / 12期
关键词
DUAL CHAMBER PACING; CAROTID SINUS HYPERSENSITIVITY; VASOVAGAL SYNDROME; ATRIOVENTRICULAR CONDUCTION PROBLEMS;
D O I
10.1111/j.1540-8159.1990.tb06942.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dual chamber pacing may sometimes be directly indicated for carotid sinus hypersensitivity, vasovagal syndrome, and certain cases of sinoatrial block and intermittent atrioventricular (AV) block, although AV conduction is dominantly normal. At times of normal AV conduction, competition between ventricular pacing and spontaneous ventricular depolarization may occur, with its adverse hemodynamic effects on ventricular function and unnecessary drainage of pacemaker battery energy. A new mode of stimulation is described, called automatic DDD mode, which functions in 'pseudo-AAI' mode during normal AV conduction and reverts to classical DDD function during episodes of AV blocks. Furthermore, during pseudo-AAI function, the pacemaker measures certain physiological parameters that serve to automatically program certain parameters used in DDD mode. Preliminary clinical evaluation has shown that this new mode functions satisfactorily.
引用
收藏
页码:2059 / 2064
页数:6
相关论文
共 10 条
[1]   COMPARISON OF THE EFFECTS OF RIGHT ATRIAL, RIGHT VENTRICULAR APEX AND ATRIOVENTRICULAR SEQUENTIAL PACING ON MYOCARDIAL OXYGEN-CONSUMPTION AND CARDIAC EFFICIENCY - A LABORATORY INVESTIGATION [J].
BALLER, D ;
WOLPERS, HG ;
ZIPFEL, J ;
BRETSCHNEIDER, HJ ;
HELLIGE, G .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (04) :394-403
[2]  
BAROLD SS, 1988, NEW PERSPECTIVES CAR
[3]   EFFECTS OF ALTERED SITE OF ELECTRICAL ACTIVATION ON MYOCARDIAL PERFORMANCE DURING INOTROPIC STIMULATION [J].
HEYNDRICKX, GR ;
VILAINE, JP ;
KNIGHT, DR ;
VATNER, SF .
CIRCULATION, 1985, 71 (05) :1010-1016
[4]  
HOOD WB, 1969, AM J PHYSIOL, V217, P215
[5]   EFFECTS OF DIFFERENT PACING MODES ON LEFT-VENTRICULAR RELAXATION IN CLOSED-CHEST DOGS [J].
LITWIN, SE ;
GORMAN, G ;
HUANG, SKS .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (07) :1070-1076
[6]   LONG-TERM PACING IN SINUS NODE DISEASE - EFFECTS OF STIMULATION MODE ON CARDIOVASCULAR MORBIDITY AND MORTALITY [J].
ROSENQVIST, M ;
BRANDT, J ;
SCHULLER, H .
AMERICAN HEART JOURNAL, 1988, 116 (01) :16-22
[7]   THE NATURAL-HISTORY OF SICK SINUS SYNDROME [J].
SUTTON, R ;
KENNY, RA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (06) :1110-1114
[8]  
TORRESANI J, 1985, CARDIAC PACING ELECT, P243
[9]   The muscular reactions of the mammalian ventricles to artificial surface stimuli [J].
Wiggers, CJ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1925, 73 (02) :346-378
[10]   RIGHT VENTRICULAR PACING REDUCES THE RATE OF LEFT-VENTRICULAR RELAXATION AND FILLING [J].
ZILE, MR ;
BLAUSTEIN, AS ;
SHIMIZU, G ;
GAASCH, WH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (03) :702-709