FAST MR CARDIAC PROFILING WITH 2-DIMENSIONAL SELECTIVE PULSES

被引:13
作者
CLINE, HE [1 ]
HARDY, CJ [1 ]
PEARLMAN, JD [1 ]
机构
[1] MASSACHUSETTS GEN HOSP,BOSTON,MA 02114
关键词
D O I
10.1002/mrm.1910170211
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A rapid‐profiling NMR pulse sequence has been designed to provide an interactive, real‐time cardiac probe analogous to M‐mode ultrasound. The pulse sequence employs a two‐dimensional (2D) selective NMR pulse to excite a narrow (nominally 1 ‐cm‐diameter) cylinder of magnetization intersecting the heart. This procedure is followed by a readout gradient applied along the length of the cylinder, or “beam,” to yield an M‐mode type profile with a one‐dimensional Fourier transform reconstruction. k‐space techniques were used to design 2D pulses which excite cylinders characterized by either Gaussian or square radial excitation profiles. Images of phantoms acquired at 1.5 T confirm the predictions of the k‐space analysis. The cylinder can be displaced interactively by modulating the rf excitation and the beam axis can be reoriented to any oblique direction by changing the relative mixing of the gradient waveforms. Flow compensation using bipolar gradient waveforms inverts the contrast of flowing blood and suppresses flow artifacts. A gated cardiac image is acquired as a reference to locate the excitation axis. A series of cardiac experiments was performed on several healthy volunteers. As the beam is moved and rotated to probe the myocardium, the profile plots resemble an M‐mode echocardiogram. Unlike in M‐mode echocardiography, however, the axis of interrogation is not limited to specific windows, and there is distinct flexibility of contrast. However, the temporal resolution is currently less than that achieved by ultrasound. NMR M‐mode profiling provides a direct, fast method of measuring heart motion to assess cardiac function as part of an MR cardiac exam. © 1991 Academic Press, Inc. Copyright © 1991 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:390 / 401
页数:12
相关论文
共 24 条
  • [1] NMR IMAGES BY MULTIPLE SENSITIVE POINT METHOD - APPLICATION TO LARGER BIOLOGICAL-SYSTEMS
    ANDREW, ER
    BOTTOMLEY, PA
    HINSHAW, WS
    HOLLAND, GN
    MOORE, WS
    SIMAROJ, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (05) : 971 - 974
  • [2] TWO-DIMENSIONAL SPATIALLY SELECTIVE SPIN INVERSION AND SPIN-ECHO REFOCUSING WITH A SINGLE NUCLEAR-MAGNETIC-RESONANCE PULSE
    BOTTOMLEY, PA
    HARDY, CJ
    [J]. JOURNAL OF APPLIED PHYSICS, 1987, 62 (10) : 4284 - 4290
  • [3] BRACEWELL RN, 1978, FOURIER TRANSFORM IT, P244
  • [4] VARIABLE-RATE SELECTIVE EXCITATION
    CONOLLY, S
    NISHIMURA, D
    MACOVSKI, A
    GLOVER, G
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03): : 440 - 458
  • [5] FEIGENBAUM H, 1972, ECHOCARDIOGRAPHY, P237
  • [6] RAPID NMR IMAGING OF DYNAMIC PROCESSES USING THE FLASH TECHNIQUE
    FRAHM, J
    HAASE, A
    MATTHAEI, D
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (02) : 321 - 327
  • [7] IMAGE-FORMATION IN NMR BY A SELECTIVE IRRADIATIVE PROCESS
    GARROWAY, AN
    GRANNELL, PK
    MANSFIELD, P
    [J]. JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1974, 7 (24): : L457 - L462
  • [8] OFF-AXIS SPATIAL LOCALIZATION WITH FREQUENCY MODULATED NUCLEAR MAGNETIC-RESONANCE ROTATING (RHO) PULSES
    HARDY, CJ
    BOTTOMLEY, PA
    ROEMER, PB
    [J]. JOURNAL OF APPLIED PHYSICS, 1988, 63 (09) : 4741 - 4743
  • [9] OPTIMIZATION OF TWO-DIMENSIONAL SPATIALLY SELECTIVE NMR PULSES BY SIMULATED ANNEALING
    HARDY, CJ
    BOTTOMLEY, PA
    ODONNELL, M
    ROEMER, P
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1988, 77 (02): : 233 - 250
  • [10] SPATIAL LOCALIZATION IN 2 DIMENSIONS USING NMR DESIGNER PULSES
    HARDY, CJ
    CLINE, HE
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1989, 82 (03): : 647 - 654