PROTECTIVE EFFECTS OF THE HEMOPUMP LEFT-VENTRICULAR ASSIST DEVICE IN EXPERIMENTAL CARDIOGENIC-SHOCK

被引:22
作者
SCHOLZ, KH
HERING, JP
SCHRODER, T
UHLIG, P
KREUZER, H
TEBBE, U
FERRARI, M
HELLIGE, G
机构
[1] Department of Cardiology, Department of Experimental Cardiology, Georg-August University, Göttingen
关键词
CARDIOGENIC SHOCK; HEMOPUMP; MECHANICAL CIRCULATORY SUPPORT; MYOCARDIAL METABOLISM; MYOCARDIAL ENERGETICS;
D O I
10.1016/1010-7940(92)90218-M
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The efficacy of the new cable-driven rotating left ventricular assist device Hemopump in cardiogenic shock was examined in experiments with adult sheep (n = 14; body weight 50-71 kg). Shock was induced by high frequency ventricular pacing. Aortic, pulmonary, central venous and left ventricular pressures as well as electromagnetic measurements of coronary blood flow were recorded continuously; cardiac output was measured by thermodilution technique. Blood samples for determination of oxygen content, electrolytes and lactate were taken under control conditions, in shock, and during pump intervention at different levels of pump speed. Vascular resistance, total body and myocardial oxygen consumption as well as myocardial uptake and release of lactate were calculated. High frequency pacing led to a significant decrease in cardiac output (from 3.8 +/- 0.8 to 2.2 +/- 1.6 l/min), mean aortic pressure (89.1 +/- 14.4 to 47.6 +/- 7.2 mmHg), and total body oxygen consumption (2.6 +/- 0.3 to 1.4 +/- 0.7 ml/min per kg), as well as myocardial release of lactate (arterial coronary-venous difference of lactate: 0.27 +/- 0.26 to -0.32 +/- 0.72 mmol/l). Hemopump assist in this condition resulted in a significant increase in cardiac output (to 2.8 +/- 0.6 l/min), mean aortic pressure (to 65.6 +/- 13.9 mmHg), and myocardial perfusion pressure (from 25.5 +/- 11.0 to 59.0 +/- 14.7), and led to nearly normal total body oxygen consumption (2.5 +/- 0.7 ml/min per kg), a decrease in myocardial oxygen consumption (from 6.1 +/- 2.1 in shock, to 4.8 +/- 1.7 ml/min per 100 g), and to normal arterial coronary-venous difference of lactate (0.24 +/- 0.26 mmol/1). Hemodynamic and metabolic data demonstrate the beneficial effects of cardiac assist with the Hemopump in tachycardia-induced severe cardiogenic shock.
引用
收藏
页码:209 / 214
页数:6
相关论文
共 25 条
[1]  
Baird R.J., Labrosse C.J., Lajos T.Z., Thomas G.W., Effects of a selective bypass of the left ventricle, Circulation, 27, pp. 835-840, (1963)
[2]  
Baller D., Hoeft A., Korb H., Wolpers H.G., Zipfel J., Heilige G., Basic physiological studies on cardiac pacing with special reference to the optimal mode and rate after cardiac surgery, Thorac Cardiovasc Surg, 29, pp. 168-173, (1981)
[3]  
Catinella F.P., Cunningham J.N., Glassman E., Laschinger J.C., Baumann F.G., Spencer F.C., Left atrium to femoral artery bypass: Effectiveness in reduction of acute experimental myocardial infarction, J Thorac Cardiovasc Surg, 86, pp. 887-896, (1983)
[4]  
Dennis C., Hall D.P., Moreno J.R., Senning A., Reduction of the oxygen utilization of the heart by left heart bypass, Circ Res, 10, pp. 298-305, (1962)
[5]  
Frazier O.H., Wampler R.K., Duncan J.M., First human use of the hemopump, a catheter mounted ventricular assist device, Ann Thorac Surg, 49, pp. 299-304, (1990)
[6]  
Gunnar R.M., Cardiogenic shock complicating acute myocardial infarction, Circulation, 78, pp. 1508-1510, (1988)
[7]  
Hering J.P., Schroder T., Uhlig P., Scholz K.H., Tebbe U., Kreuzer H., Heilige G., Myocardial support and protection during regional myocardial ischemia using the Hemopump assist device, Thorac Cardiovasc Surg, 39, pp. 257-262, (1991)
[8]  
Kantrowitz A., Circulatory support - State of the art, Trans Am Soc Artif Intern Organs, 34, pp. 445-449, (1988)
[9]  
Kebbel U., Hirche H.J., An electromagnetic distance measuring system, Med Progr Technol, 10, pp. 213-223, (1985)
[10]  
Laas J., Campbell C.D., Takanashi Y., Pick R., Replogle R.L., Sebening F., Critical analysis of intra-aortic balloon counterpulsation and transapical left ventricular bypass in the sufficient and insufficient circulation, Thorac Cardiovasc Surg, 29, pp. 17-31, (1981)