EVALUATION OF CONVENTIONAL PRESS-AND-BREATHE METERED-DOSE INHALER TECHNIQUE IN 501 PATIENTS

被引:85
作者
LARSEN, JS
HAHN, M
EKHOLM, B
WICK, KA
机构
[1] College of Pharmacy, University of Minnesota, Minneapolis, MN
[2] 3M Pharmaceuticals St. Paul, Minneapolis, MN
关键词
D O I
10.3109/02770909409044826
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Conventional press-and-breathe metered dose inhalers (MDIs) are widely prescribed but are often difficult for many patients to properly use. A total of 501 patients from different medical specialties were enrolled in this study, which evaluated how the patients used their MDIs. Using a conservative method (minimum number of errors) of determining errors, we found that 388 (77.5%) of the patients made at least one error when demonstrating how they use their MDI for two observers. Using a liberal (maximum number of errors) method of analysis, we found that 447 (89.2%) of the patients made at least one error. There was no difference in errors made stratified by patient gender, patient age, or the medical specialty that treated the patient's pulmonary disease. The two most common errors made the patients were failure to breathe out to functional residual capacity before actuation (225 by minimum method, 280 by maximum method) and not actuating the canister at the start of inhalation (207 by minimum method, 323 by maximum method). Of the patients with improper timing of actuation, the majority (121 patients by minimum method and 187 patients by maximum method) actuated the canister early. In this large patient sample, regardless of which medical specialty provided the treatment, the majority of the patients evaluated had less than optimal MDI technique. Routine assessment of MDI technique should be instituted as standard practice care.
引用
收藏
页码:193 / 199
页数:7
相关论文
共 10 条
[1]  
Wardnab A.G., Cooke N.J., Bronchodilator therapy in general practice—What are the problems?, Practitioner, 229, pp. 631-635, (1985)
[2]  
Boe J., Treatment of acute asthma in outpatient care, Pharmacological Treatment of Bronchial Asthma, 3, pp. 95-105, (1986)
[3]  
Orehek J., Gayrard P., Grimaude C.H., Patient error in use of bronchodilator metered aerosols, Br Med J, 1, (1976)
[4]  
Paterson I.C., Crompton G.K., Use of pressurized aerosols by asthmatic patients, Br Med J, 1, pp. 76-77, (1976)
[5]  
Epstein S.W., Manning C.P.R., Ashley M.J., Survey of the clinical use of pressurized aerosol inhalers, Can Med Assoc J, 120, pp. 813-816, (1979)
[6]  
Crompton G.K., Problems patients have using pressurized aerosol inhalers, Eur J Respir Dis, 63, 119, pp. 101-104, (1982)
[7]  
Larson J.S., Hahn M., Kochevar J.W., Morris R.J., Kaiser H.B., Weisberg S.C., Halverson P.C., Quessy S.N., Administration errors with a conventional metered dose inhaler versus a novel breath actuated device, Ann Allergy, 71, pp. 103-106, (1993)
[8]  
Larsen J.S., Hahn M., Kochevar J.W., Morris R.J., Kaiser H.B., Weisberg S.C., Halverson P.C., Quessy S.N., Types of errors with metered dose inhaler use in experienced and naive users, Immunol Allergy Pract, 13, (1991)
[9]  
Newman S.P., Pavia D., Clarke S.W., How should a pressurized beta adrenergic bronchodilator be inhaled?, Eur J Respir Dis, 62, pp. 3-21, (1981)
[10]  
National Heart, Lung and Blood Institute National Asthma Education Report, J Allergy Clin Immunol, 88, (1991)