THE INTERNAL SURFACE REVERSE PHASE - CONCEPTS AND APPLICATIONS

被引:28
作者
PERRY, JA
机构
[1] Regis Chemical Company, Morton Grove, Illinois 60053
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1990年 / 13卷 / 06期
关键词
D O I
10.1080/01483919008049234
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Patented in 1985, introduced commercially in 1966, internal-surface reversed phase (ISRP) supports have attracted wide attention. ISRP supports allow the analysis of serum and plasma samples by high pressure liquid chromatography (HPlC) without requiring the prior removal of protein. Proteins cannot enter the pores of ISRP supports and are not adsorbed by ISRP outer surfaces; proteins pass right through ISRP HPLC columns. Therefore, the number of serum injections that given ISRP-guarded ISRP columns can receive runs into the thousands; ISRP columns nicely lend themselves to automation. ISRP indifference to proteins is complemented by the remarkable selectivity toward drugs of its stationary phase, glycine-phenylalanine-phenylalanine (GFF), a selectivity that recently has been shown to extend to peptides. More recently still, it has been shown that ISRP columns can be used to analyze both the free and the bound forms of drugs, even distinguishing among different bound forms. A potential new intrinsically monomeric GFF shows improved retention and surprisingly high chromatographic efficiency. © 1990, Taylor & Francis Group, LLC. All rights reserved.
引用
收藏
页码:1047 / 1074
页数:28
相关论文
共 41 条
[1]   AN INVESTIGATION OF THE SIZE, SHAPE AND HYDRATION OF SERUM ALBUMIN BY SMALL-ANGLE X-RAY SCATTERING [J].
ANDEREGG, JW ;
BEEMAN, WW ;
SHULMAN, S ;
KAESBERG, P .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1955, 77 (11) :2927-2937
[2]   PROCEDURES FOR DIRECT INJECTIONS OF UNTREATED BLOOD-PLASMA INTO LIQUID-CHROMATOGRAPHIC COLUMNS WITH EMPHASIS ON A PRE-COLUMN VENTING TECHNIQUE [J].
ARVIDSSON, T ;
WAHLUND, KG ;
DAOUD, N .
JOURNAL OF CHROMATOGRAPHY, 1984, 317 (DEC) :213-226
[3]  
BETHELL GS, 1979, J BIOL CHEM, V254, P2572
[4]   THE USE OF A PRE-COLUMN FOR THE DIRECT HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF THE ANTI-DEPRESSANTS CLOVOXAMINE AND FLUVOXAMINE IN PLASMA [J].
DEJONG, GJ .
JOURNAL OF CHROMATOGRAPHY, 1980, 183 (02) :203-211
[5]   INTERNAL SURFACE REVERSED-PHASE SILICA SUPPORTS FOR LIQUID-CHROMATOGRAPHY [J].
HAGESTAM, IH ;
PINKERTON, TC .
ANALYTICAL CHEMISTRY, 1985, 57 (08) :1757-1763
[6]  
HEARN MTW, 1982, ADV CHROMATOGR, V20, P4
[7]  
Hofmann K, 1940, J BIOL CHEM, V134, P225
[8]   PRE-COLUMNS OF AMBERLITE XAD-2 FOR DIRECT INJECTION LIQUID-CHROMATOGRAPHIC DETERMINATION OF METHAQUALONE IN BLOOD-PLASMA [J].
HUX, RA ;
MOHAMMED, HY ;
CANTWELL, FF .
ANALYTICAL CHEMISTRY, 1982, 54 (01) :113-117
[9]   ROUTINE DETERMINATION OF 8 COMMON ANTI-EPILEPTIC DRUGS AND METABOLITES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING A COLUMN-SWITCHING SYSTEM FOR DIRECT INJECTION OF SERUM SAMPLES [J].
JUERGENS, U .
JOURNAL OF CHROMATOGRAPHY, 1984, 310 (01) :97-106
[10]  
LASSEN PO, 1983, ADV CHROMATOGR, V21, P41