EFFECT OF SCANNING PRESSURE ON INTRACRANIAL HEMODYNAMICS DURING TRANSFONTANELLAR DUPLEX US

被引:26
作者
TAYLOR, GA [1 ]
机构
[1] JOHNS HOPKINS MED INST, DEPT PEDIAT, BALTIMORE, MD 21205 USA
关键词
BLOOD; FLOW DYNAMICS; BLOOD VESSELS; US; ULTRASOUND US; DOPPLER STUDIES; ULTRASOUND (US) IN INFANTS AND CHILDREN;
D O I
10.1148/radiology.185.3.1438759
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to determine the effect of transducer scanning pressure during duplex ultrasonographic evaluation of intracranial hemodynamics in new-borns. Doppler spectra were obtained from the anterior cerebral artery with use of light and firm scanning pressure over the anterior fontanelle in 23 healthy infants and 20 infants with reduced cranial compliance due to ventricular dilatation, intracranial hemorrhage, diffuse cerebral edema, and extraaxial fluid. In healthy infants, the mean resistive index (RI) increased from 69.9 +/- 3 to 74.8 +/- 3 (P < .005), and mean time average velocity (TAV) decreased from 11.1 cm/sec +/- 1.3 to 8.6 cm/sec +/- 1.3 (P < .0001) with firm scanning pressure. In infants with decreased cranial compliance, mean RI increased from 67.8 +/- 4 to 85 +/- 5, and mean TAV decreased from 16.3 cm/sec +/- 2 to 10.7 cm/sec +/- 2 (P < .0001 for both comparisons). A significant alteration in RI with firm technique (greater-than-or-equal-to 20% increase in RI, or reversal of diastolic flow) was observed in 12 of 28 examinations in infants with decreased cranial compliance and in only one of 23 healthy infants (P < .005). These data show that scanning pressures during duplex ultrasonography can significantly affect intracranial hemodynamics, especially in infants with altered cranial compliance.
引用
收藏
页码:763 / 766
页数:4
相关论文
共 23 条
[1]  
AHMANN PA, 1983, PEDIATRICS, V72, P665
[2]   NON-INVASIVE DIAGNOSIS OF NEONATAL ASPHYXIA AND INTRA-VENTRICULAR HEMORRHAGE BY DOPPLER ULTRASOUND [J].
BADA, HS ;
HAJJAR, W ;
CHUA, C ;
SUMNER, DS .
JOURNAL OF PEDIATRICS, 1979, 95 (05) :775-779
[3]   INTRA-CRANICAL PRESSURE AND CEREBRAL ARTERIAL PULSATILE FLOW MEASUREMENTS IN NEONATAL INTRAVENTRICULAR HEMORRHAGE [J].
BADA, HS ;
MILLER, JE ;
MENKE, JA ;
MENTEN, TG ;
BASHIRU, M ;
BINSTADT, D ;
SUMNER, DS ;
KHANNA, NN .
JOURNAL OF PEDIATRICS, 1982, 100 (02) :291-296
[4]   REGIONAL CEREBRAL BLOOD-FLOW, CEREBRAL BLOOD VELOCITY, AND PULSATILITY INDEX IN NEWBORN DOGS [J].
BATTON, DG ;
HELLMANN, J ;
HERNANDEZ, MJ ;
MAISELS, MJ .
PEDIATRIC RESEARCH, 1983, 17 (11) :908-912
[5]  
Bruce D A, 1977, Adv Pediatr, V24, P233
[6]   HEAD POSITION AFFECTS INTRACRANIAL-PRESSURE IN NEWBORN-INFANTS [J].
EMERY, JR ;
PEABODY, JL .
JOURNAL OF PEDIATRICS, 1983, 103 (06) :950-953
[7]   BRAIN-DEATH IN INFANTS - EVALUATION WITH DOPPLER US [J].
GLASIER, CM ;
SEIBERT, JJ ;
CHADDUCK, WM ;
WILLIAMSON, SL ;
LEITHISER, RE .
RADIOLOGY, 1989, 172 (02) :377-380
[8]   CRANIAL DUPLEX SONOGRAPHY OF THE INFANT [J].
GRANT, EG ;
WHITE, EM ;
SCHELLINGER, D ;
CHOYKE, PL ;
SARCONE, AL .
RADIOLOGY, 1987, 163 (01) :177-185
[9]   CEREBRAL BLOOD-FLOW IN THE NEWBORN-INFANT - COMPARISON OF DOPPLER ULTRASOUND AND XE-133 CLEARANCE [J].
GREISEN, G ;
JOHANSEN, K ;
ELLISON, PH ;
FREDRIKSEN, PS ;
MALI, J ;
FRIISHANSEN, B .
JOURNAL OF PEDIATRICS, 1984, 104 (03) :411-418
[10]  
HANSEN NB, 1983, PEDIATRICS, V72, P526