SILICONE BREAST IMPLANTS - US EVALUATION

被引:57
作者
DEBRUHL, ND
GORCZYCA, DP
AHN, CY
SHAW, WW
BASSETT, LW
机构
[1] UNIV CALIF LOS ANGELES,SCH MED,DIV PLAST SURG,LOS ANGELES,CA 90024
[2] UNIV CALIF LOS ANGELES,SCH MED,JONSSON COMPREHENS CANC CTR,LOS ANGELES,CA 90024
关键词
BREAST; PROSTHESES; SURGERY; US;
D O I
10.1148/radiology.189.1.8372224
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the value of breast ultrasonography (US) in the assessment of silicone breast implants for rupture. MATERIALS AND METHODS: Seventy-four women with local or systemic symptoms related to silicone implants underwent breast US. Of these, 28 underwent surgical removal of the implants. RESULTS: Of 57 implants removed, 37 were intact. The most reliable sign of an intact implant was an anechoic interior, although reverberation artifact and radial folds could be seen. Of 20 ruptured implants, 16 were intracapsular and four were extracapsular ruptures. The most reliable US sign of rupture was echogenic, horizontal (''stepladder'') lines (14 of 20 ruptures). Two of the four extracapsular ruptures were accurately identified as echogenic nodules outside the implant; two were false-negative findings. Three intracapsular ruptures identified at US were false-positive; six were false-negative. Overall sensitivity for rupture was 70%, specificity was 92%, positive predictive value was 82%, and negative predictive value was 85%. CONCLUSION: Breast US is capable of depicting intracapsular and extra-capsular rupture of breast implants.
引用
收藏
页码:95 / 98
页数:4
相关论文
共 19 条
[1]   THE DIAGNOSIS OF RUPTURED BREAST IMPLANTS [J].
ANDERSEN, B ;
HAWTOF, D ;
ALANI, H ;
KAPETANSKY, D .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1989, 84 (06) :903-907
[2]  
BAKER JL, 1976, PLAST RECONSTR SURG, V58, P137
[3]  
BASSETT LW, 1992, AM J ROENTGENOL, V159, P979
[4]   BREAST AUGMENTATION - A RISK FACTOR FOR BREAST-CANCER [J].
BERKEL, H ;
BIRDSELL, DC ;
JENKINS, H .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 326 (25) :1649-1653
[5]   FACT AND FICTION ABOUT BREAST IMPLANT BLEED [J].
BRODY, GS .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1977, 60 (04) :615-616
[6]  
CRONIN TD, 1964, 3RD T INT C PLAST SU, P41
[7]   SILICONE AND RHEUMATIC DISEASES [J].
ENDO, LP ;
EDWARDS, NL ;
LONGLEY, S ;
CORMAN, LC ;
PANUSH, RS .
SEMINARS IN ARTHRITIS AND RHEUMATISM, 1987, 17 (02) :112-118
[8]   AUGMENTATION MAMMAPALSTY - NORMAL AND ABNORMAL FINDINGS WITH MAMMOGRAPHY AND ULTRASOUND [J].
GANOTT, MA ;
HARRIS, KM ;
ILKHANIPOUR, ZS ;
COSTAGRECO, MA .
RADIOGRAPHICS, 1992, 12 (02) :281-295
[9]   SILICONE BREAST IMPLANTS INVIVO - MR IMAGING [J].
GORCZYCA, DP ;
SINHA, S ;
AHN, CY ;
DEBRUHL, ND ;
HAYES, MK ;
GAUSCHE, VR ;
SHAW, WW ;
BASSETT, LW .
RADIOLOGY, 1992, 185 (02) :407-410
[10]  
Gruber R P, 1981, Ann Plast Surg, V6, P271, DOI 10.1097/00000637-198104000-00003