EFFECTIVENESS OF TUNED LIQUID DAMPERS UNDER WIND EXCITATION

被引:167
作者
TAMURA, Y
FUJII, K
OHTSUKI, T
WAKAHARA, T
KOHSAKA, R
机构
[1] WIND ENGN INST CO LTD,CHIYODA KU,TOKYO,JAPAN
[2] SHIMIZU CORP,DIV TECHNOL DEV,MINATO KU,TOKYO 135,JAPAN
[3] SHIMIZU CORP,INST TECHNOL,TOKYO,JAPAN
[4] AZUSA SEKKEI CO LTD,TOKYO,JAPAN
关键词
TUNED LIQUID DAMPERS; SLOSHING MOTION; VIBRATION CONTROL; DAMPING RATIO; WIND-INDUCED RESPONSES; FULL-SCALE MEASUREMENTS; TALL BUILDINGS; SERVICEABILITY;
D O I
10.1016/0141-0296(95)00031-2
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Full-scale measurements of the wind-induced responses of four buildings (two airport towers, an observatory tower and a high-rise hotel) were conducted to prove the efficiency of tuned liquid dampers (TLDs). The damping ratios of the buildings with and without TLD were evaluated by both the run-down test technique and the random decrement technique. The wind-induced responses of the buildings were measured before and after installation of TLDs. The exceedance frequency of the response over the human perception thresholds was also examined. The results obtained in this study demonstrate that the TLDs could significantly improve the serviceability of the buildings.
引用
收藏
页码:609 / 621
页数:13
相关论文
共 13 条
[1]   ANALYTICAL DESIGN OF OPTIMAL NUTATION DAMPERS [J].
AMIEUX, JC ;
DUREIGNE, M .
JOURNAL OF SPACECRAFT AND ROCKETS, 1972, 9 (12) :934-935
[2]  
Bhutta PG., 1966, INT J MECH SCI, V8, P383
[3]   DAMPING IN TALL BUILDINGS - A MECHANISM AND A PREDICTOR [J].
JEARY, AP .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1986, 14 (05) :733-750
[4]  
KANDA J, 1994, APR ASCE STRUCT C IA, P648
[5]  
MODI VJ, 1980, 4TH P C IND AER AACH, V2, P270
[6]  
Organization WHOA FA Report of a Joint FAO, 2002, GUIDELINES EVALUATIO
[7]  
TAMURA Y, 1994, JUL E EUR C WIND E 1, P175
[8]  
TAMURA Y, 1991, 8TH P INT C WIND ENG, V43, P1919
[9]  
TAMURA Y, 1995, 9 INT C WIND ENG, V3, P1396
[10]  
TAMURA Y, 1988, MAY P S WORKSH SERV, V1, P228