LINEAR FLOW GRADIENTS FOR AUTOMATIC TITRATIONS

被引:19
作者
GARCIA, IL [1 ]
VINAS, P [1 ]
CAMPILLO, N [1 ]
CORDOBA, MH [1 ]
机构
[1] UNIV MURCIA,FAC CHEM,DEPT ANALYT CHEM,E-30071 MURCIA,SPAIN
关键词
FLOW SYSTEM; TITRIMETRY; AUTOMATION;
D O I
10.1016/0003-2670(94)00629-Z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A manifold to perform automatic continuous flow titrations is presented. The system is based on the use of a variable-speed peristaltic pump which delivers the titrant at a linearly increasing now rate and another pump working at a constant and higher speed, placed after the detector, the difference between both flow rates being compensated by the aspiration of the titrand through a T-piece. A solution containing the indicator is also propelled by the fixed speed pump. With such an arrangement, the flow rate through the spectrophotometric cell is constant and there is no drift of the baseline. The equations describing the behaviour of such a system are first obtained and then experimentally checked by using both acid-base and complexometric titrations. The experiments prove that the approach is highly reproducible (relative standard deviations (R.S.D.) below +/-1.5%), but inaccurate, since the time necessary to reach the equivalence point is longer than that predicted by theory. To avoid the need of a previous calibration, a second gradient can be performed by decreasing the variable-pump speed to zero. In this way, two equivalence points are obtained. Since both gradients are diametrically opposite, the difference in time between the two equivalence points agrees with that predicted by theory, as the errors can only cancel each other out. For acid-base and complexometric titrations the errors are below +/-2%.
引用
收藏
页码:67 / 76
页数:10
相关论文
共 23 条
[1]   ANALYTICAL POTENTIAL OF FLOW GRADIENTS IN UNSEGMENTED FLOW SYSTEMS [J].
AGUDO, M ;
MARCOS, J ;
RIOS, A ;
VALCARCEL, M .
ANALYTICA CHIMICA ACTA, 1990, 239 (02) :211-220
[2]   CONTINUOUS AUTOMATED BURETLESS TITRATOR WITH DIRECT READOUT [J].
BLAEDEL, WJ ;
LAESSIG, RH .
ANALYTICAL CHEMISTRY, 1964, 36 (08) :1617-&
[3]   FLOW METHOD FOR THE TITRATION OF WEAK ACIDS OR WEAK BASES USING LINEAR TITRATION PLOTS [J].
CALATAYUD, JM ;
FALCO, PC ;
ALBERT, RM .
ANALYST, 1987, 112 (07) :1063-1066
[4]   IODIMETRIC DETERMINATION OF PENICILLINS BY A TRIANGLE PROGRAMMED FLOW-THROUGH TITRATION TECHNIQUE [J].
FEHER, Z ;
KOLBE, I ;
PUNGOR, E .
ANALYST, 1988, 113 (06) :881-884
[5]   DETERMINATION OF THE DRUG CONTENT OF PHARMACEUTICALS CONTAINING PHENOTHIAZINE COMPOUNDS BY TRIANGLE PROGRAMMED FLOW TITRATION [J].
FEHER, Z ;
KOLBE, I ;
PUNGOR, E .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 332 (04) :345-350
[6]   APPLICATION OF FLOW-THROUGH TECHNIQUES TO DRUG DISSOLUTION STUDIES [J].
FEHER, Z ;
KOLBE, I ;
PUNGOR, E .
ANALYST, 1991, 116 (05) :483-487
[7]   GRADIENT TITRATION - NOVEL APPROACH TO CONTINUOUS MONITORING USING ION-SELECTIVE ELECTRODES [J].
FLEET, B ;
HO, AYW .
ANALYTICAL CHEMISTRY, 1974, 46 (01) :9-11
[8]   VOLUMETRIC TRIANGLE-PROGRAMMED FLOW TITRATIONS BASED ON PRECISELY GENERATED CONCENTRATION GRADIENTS [J].
FUHRMANN, B ;
SPOHN, U .
ANALYTICA CHIMICA ACTA, 1993, 282 (02) :397-406
[9]   CALIBRATION IN FLAME ATOMIC-ABSORPTION SPECTROMETRY USING A SINGLE STANDARD AND A GRADIENT TECHNIQUE [J].
GARCIA, IL ;
VINAS, P ;
CORDOBA, MH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (04) :553-561
[10]   AUTOMATIC TITRATIONS IN UNSEGMENTED FLOW SYSTEMS BASED ON VARIABLE FLOW-RATE PATTERNS .1. PRINCIPLES AND APPLICATIONS TO ACID-BASE TITRATIONS [J].
MARCOS, J ;
RIOS, A ;
VALCARCEL, M .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :489-494