PICOSECOND PHOTOCONDUCTIVE SAMPLING WITH NANOSECOND CARRIER LIFETIMES USING AN INTEGRATED INDUCTIVE LOOP

被引:6
作者
DAVIDSON, AC [1 ]
WISE, FW [1 ]
COMPTON, RC [1 ]
机构
[1] CORNELL UNIV,SCH ELECT ENGN,ITHACA,NY 14853
关键词
D O I
10.1063/1.113185
中图分类号
O59 [应用物理学];
学科分类号
摘要
A noninvasive, photoconductive sampling technique, which does not require short-lifetime material to achieve picosecond temporal resolution, is demonstrated. The technique relies on electromagnetic coupling to generate the time derivative of the signal of interest in a separate sampling circuit. A slow photoconductive device in the sampling circuit integrates the coupled signal to produce the desired wave form. A 5-ps sampling response (limited only by circuit parasitics) was measured on GaAs with a lifetime of 1 ns by coupling to a small conducting loop.© 1995 American Institute of Physics.
引用
收藏
页码:2259 / 2261
页数:3
相关论文
共 11 条
  • [1] PICOSECOND OPTICAL ELECTRONIC SAMPLING - CHARACTERIZATION OF HIGH-SPEED PHOTODETECTORS
    AUSTON, DH
    SMITH, PR
    [J]. APPLIED PHYSICS LETTERS, 1982, 41 (07) : 599 - 601
  • [2] IMPULSE-RESPONSE OF PHOTOCONDUCTORS IN TRANSMISSION-LINES
    AUSTON, DH
    [J]. IEEE JOURNAL OF QUANTUM ELECTRONICS, 1983, 19 (04) : 639 - 648
  • [3] AUSTON DH, 1988, ULTRASHORT LASER PUL, P183
  • [4] CAPACITANCE FREE GENERATION AND DETECTION OF SUBPICOSECOND ELECTRICAL PULSES ON COPLANAR TRANSMISSION-LINES
    GRISCHKOWSKY, DR
    KETCHEN, MB
    CHI, CC
    DULING, IN
    HALAS, NJ
    HALBOUT, JM
    MAY, PG
    [J]. IEEE JOURNAL OF QUANTUM ELECTRONICS, 1988, 24 (02) : 221 - 225
  • [5] ELECTROOPTIC SAMPLING IN GAAS INTEGRATED-CIRCUITS
    KOLNER, BH
    BLOOM, DM
    [J]. IEEE JOURNAL OF QUANTUM ELECTRONICS, 1986, 22 (01) : 79 - 93
  • [6] PICOSECOND PULSE RESPONSE CHARACTERISTICS OF GAAS METAL-SEMICONDUCTOR-METAL PHOTODETECTORS
    MOGLESTUE, C
    ROSENZWEIG, J
    KUHL, J
    KLINGENSTEIN, M
    LAMBSDORFF, M
    AXMANN, A
    SCHNEIDER, J
    HULSMANN, A
    [J]. JOURNAL OF APPLIED PHYSICS, 1991, 70 (04) : 2435 - 2448
  • [7] DIFFERENTIAL PHOTOCONDUCTIVE SAMPLING WITH A RESOLUTION INDEPENDENT OF CARRIER LIFETIME
    PASLASKI, J
    YARIV, A
    [J]. APPLIED PHYSICS LETTERS, 1989, 55 (17) : 1744 - 1746
  • [8] PICOSECOND GAAS-BASED PHOTOCONDUCTIVE OPTOELECTRONIC DETECTORS
    SMITH, FW
    LE, HQ
    DIADIUK, V
    HOLLIS, MA
    CALAWA, AR
    GUPTA, S
    FRANKEL, M
    DYKAAR, DR
    MOUROU, GA
    HSIANG, TY
    [J]. APPLIED PHYSICS LETTERS, 1989, 54 (10) : 890 - 892
  • [9] SUBPICOSECOND ELECTROOPTIC SAMPLING - PRINCIPLES AND APPLICATIONS
    VALDMANIS, JA
    MOUROU, G
    [J]. IEEE JOURNAL OF QUANTUM ELECTRONICS, 1986, 22 (01) : 69 - 78
  • [10] PICOSECOND ELECTROOPTIC SAMPLING SYSTEM
    VALDMANIS, JA
    MOUROU, G
    GABEL, CW
    [J]. APPLIED PHYSICS LETTERS, 1982, 41 (03) : 211 - 212