SHAPES OF FLOW-INJECTION SIGNALS - EFFECT OF REFRACTIVE-INDEX ON SPECTROPHOTOMETRIC SIGNALS OBTAINED FOR ONLINE FORMATION OF BROMINE FROM BROMATE, BROMIDE AND HYDROGEN-ION IN A SINGLE-CHANNEL MANIFOLD USING LARGE-VOLUME TIME-BASED INJECTIONS

被引:11
作者
FOGG, AG
CIPKO, E
FARABELLA, L
TYSON, JF
机构
[1] Chemistry Department, Loughborough University of Technology
[2] Department of Chemistry, University of Massachusetts, Amherst
关键词
Flow injection; Large-volume and time-based injections; On-line bromine formation; Refractive index effect; Spectrophotometric detection;
D O I
10.1039/an9901500593
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The shapes of the spectrophotometric signals obtained with a single-channel manifold for large-volume (4 ml) time-based injections for the six possible combinations of the reagents bromate, bromide and nitric acid in the injectate and carrier stream, by which bromine can be formed on-line, have been determined. The injectate and carrier stream were 5.25 × 10-4 M in bromate, 0.030 M in bromide and 1 M in nitric acid when these reagents were present. The signals consisted of two separate peaks caused by formation of bromine at the front and rear boundaries of the injected bolus. When both injectate and carrier stream were 1 M in nitric acid (i.e., for the reagent combination H+BrO3- -H+Br -)the two peaks were of equal height, and the signal was virtually the same whichever solution was used as the injectate. In reagent combinations where only one solution contained nitric acid the peaks were different in size, the smaller peak being that produced by the boundary in which the acidic solution was flowing behind the other solution. This difference in size between the front and rear peaks was shown to be caused by refractive index effects. When the refractive indices of the two solutions were matched either by increasing the potassium bromide concentration or by making the non-acidic solution 7% in sodium nitrate, the peaks became equal in size. When the potassium bromide concentration was increased there was an appreciable increase in peak size (about 4-fold): the changes in the amount of bromine formed must be due to kinetic or equilibrium effects. This increase in size did not occur when sodium nitrate was used to balance the refractive indices.
引用
收藏
页码:593 / 597
页数:5
相关论文
共 8 条
[1]  
BETTERIDGE D, 1978, ANALYST, V103, P897, DOI 10.1039/an9780300897
[2]   IODIMETRIC AND BROMIMETRIC FLOW-INJECTION AMPEROMETRIC METHODS OF DETERMINING SULFITE IN WHICH IODINE OR BROMINE IS MONITORED AT A GLASSY-CARBON ELECTRODE [J].
FOGG, AG ;
GUTA, CW ;
CHAMSI, AY .
ANALYST, 1987, 112 (03) :253-258
[3]   SHAPES OF NORMAL AND REVERSE FLOW-INJECTION SIGNALS - ONLINE FORMATION OF IODINE FROM IODATE, IODIDE AND HYDROGEN-ION WITH DETECTION BY VISIBLE SPECTROPHOTOMETRY [J].
FOGG, AG ;
WANG, XW ;
TYSON, JF .
ANALYST, 1989, 114 (09) :1119-1123
[5]   ELIMINATION OF DOUBLE PEAKS IN THE IODIMETRIC FLOW-INJECTION VISIBLE SPECTROPHOTOMETRIC DETERMINATION OF SULFITE USING A SINGLE-CHANNEL MANIFOLD [J].
FOGG, AG ;
WANG, XW ;
TYSON, JF .
ANALYST, 1990, 115 (03) :305-307
[6]   SEQUENTIAL FLOW-INJECTION VOLTAMMETRIC DETERMINATION OF PHOSPHATE AND NITRITE BY INJECTION OF REAGENTS INTO A SAMPLE STREAM [J].
FOGG, AG ;
BSEBSU, NK .
ANALYST, 1984, 109 (01) :19-21
[7]   ONLINE BROMIMETRIC DETERMINATION OF PHENOL, ANILINE, ASPIRIN AND ISONIAZID USING FLOW-INJECTION VOLTAMMETRY [J].
FOGG, AG ;
ALI, A ;
ABDALLA, MA .
ANALYST, 1983, 108 (1288) :840-846
[8]   INDIRECT FLOW-INJECTION VOLTAMMETRIC DETERMINATION OF AROMATIC-AMINES BY MONITORING AT A GLASSY-CARBON ELECTRODE THE EXCESS OF NITRITE REMAINING AFTER THEIR DIAZOTIZATION [J].
FOGG, AG ;
BSEBSU, NK ;
ABDALLA, MA .
ANALYST, 1982, 107 (1281) :1462-1465