WHOLE-BLOOD ACTIVATED CLOTTING TIME IN INFANTS DURING EXTRACORPOREAL MEMBRANE-OXYGENATION

被引:27
作者
GREEN, TP
ISHAMSCHOPF, B
STEINHORN, RH
SMITH, C
IRMITER, RJ
机构
[1] UNIV MINNESOTA,DEPT PAEDIAT,MINNEAPOLIS,MN 55455
[2] UNIV MINNESOTA,DEPT SURG,MINNEAPOLIS,MN 55455
[3] UNIV MINNESOTA,DEPT CARDIORESP SERV,MINNEAPOLIS,MN 55455
[4] UNIV MINNESOTA,VARIETY CLUB CHILDRENS HOSP,MINNEAPOLIS,MN 55455
[5] UNIV MINNESOTA,MINNEAPOLIS CHILDRENS MED CTR,MINNEAPOLIS,MN 55455
[6] UNIV MINNESOTA,MINNESOTA LEG ECMO PROGRAM,MINNEAPOLIS,MN 55455
关键词
D O I
10.1097/00003246-199005000-00006
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Bleeding complications are the principal cause of morbidity and mortality in infants treated with extracorporeal membrane oxygenation (ECMO). The whole blood activated clotting time (ACT) test is used universally to monitor heparin therapy during this procedure. To enhance our understanding of this test and improve our management of anticoagulation, we studied the relationship between the ACT and blood heparin concentration in nine infants during ECMO. The activated clotting time correlated with the simultaneously determined heparin concentration (r = .55, p < .001 for all patient samples; r = . 92, p < .001 for mean patient values). Within the range of values found in our patients, platelet count, fibrinogen, and fibrin degradation products did not affect the ACT-heparin concentration relationship. However, the interpretation of an individual ACT result was limited by its low precision: the mean difference of duplicate determinations was 9.2%, and the estimation of heparin concentration by a single ACT had a coefficient of variation of 32%. Two commercially available techniques using different activators gave results that differed numerically but correlated well with each other. Both provided similar precision in the estimation of heparin concentration. The ACT is a low cost, bedside test whose accuracy and precision allow the achievement of target heparin concentrations required in infants during ECMO. Multiple determinations, either in duplicate or serially, are needed to achieve satisfactory precision. These data will be useful in designing future studies to determine the optimal serum heparin concentration to provide adequate anticoagulation, but avoid bleeding complications.
引用
收藏
页码:494 / 498
页数:5
相关论文
共 20 条
  • [1] EXTRACORPOREAL MEMBRANE-OXYGENATION (ECMO) IN NEONATAL RESPIRATORY-FAILURE - 100 CASES
    BARTLETT, RH
    GAZZANIGA, AB
    TOOMASIAN, J
    CORWIN, AG
    ROLOFF, D
    RUCKER, R
    [J]. ANNALS OF SURGERY, 1986, 204 (03) : 236 - 245
  • [2] A BRAIN EXTRACT AS A SUBSTITUTE FOR PLATELET SUSPENSIONS IN THE THROMBOPLASTIN GENERATION TEST
    BELL, WN
    ALTON, HG
    [J]. NATURE, 1954, 174 (4436) : 880 - 881
  • [3] BOUNAMEAUX H, 1980, AM J CLIN PATHOL, V74, P68
  • [4] CLAUSS A., 1957, ACTA HAEMATOL, V17, P237
  • [5] ESPISITO RA, 1983, J THORAC CARDIOVASC, V85, P174
  • [6] ACTIVATED COAGULATION TIME OF WHOLE BLOOD
    HATTERSLEY, PG
    [J]. JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1966, 196 (05) : 436 - +
  • [7] SIMPLE METHOD OF HEPARIN MANAGEMENT DURING PROLONGED EXTRACORPOREAL CIRCULATION
    HILL, JD
    DONTIGNY, L
    DELEVAL, M
    MIELKE, CH
    [J]. ANNALS OF THORACIC SURGERY, 1974, 17 (02) : 129 - 134
  • [8] KESTEVEN PJ, 1986, J CARDIOVASC SURG, V27, P85
  • [9] MORTALITY WITH EXTRACORPOREAL MEMBRANE-OXYGENATION FOLLOWING REPAIR OF CONGENITAL DIAPHRAGMATIC-HERNIA IN 93 INFANTS
    LANGHAM, MR
    KRUMMEL, TM
    BARTLETT, RH
    DRUCKER, DEM
    TRACY, TF
    TOOMASIAN, JM
    GREENFIELD, LJ
    SALZBERG, AM
    [J]. JOURNAL OF PEDIATRIC SURGERY, 1987, 22 (12) : 1150 - 1154
  • [10] MACDONALD MM, 1981, PEDIATR RES, V15, P1015