SYSTEMS-ANALYSIS OF CEREBROVASCULAR PRESSURE TRANSMISSION - AN OBSERVATIONAL STUDY IN HEAD-INJURED PATIENTS

被引:69
作者
PIPER, IR [1 ]
MILLER, JD [1 ]
DEARDEN, NM [1 ]
LEGGATE, JRS [1 ]
ROBERTSON, I [1 ]
机构
[1] UNIV EDINBURGH,DEPT CLIN NEUROSCI,EDINBURGH EH8 9YL,MIDLOTHIAN,SCOTLAND
关键词
Blood pressure; Cerebrovascular bed; Head injury; Intracranial pressure; Systems analysis; Waveform analysis;
D O I
10.3171/jns.1990.73.6.0871
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
In an observational study in head-injured patients, cerebrovascular pressure transmission was investigated using a systems analysis approach whereby the blood pressure (BP) waveform was used as a measure of an input stimulus to the cerebrovascular bed (CVB) and the intracranial pressure (ICP) waveform as the response to that stimulus. The transfer function is a measure of how much pressure is transmitted through the CVB at a given frequency and is calculated using Fourier analysis of the pressure waveforms. The transfer function allows quantification of the pressure transmission performance of the CVB, thus providing a basis for comparison between normal and abnormal function. Fifteen hundred samples of ICP and BP waveforms were collected from 30 head-injured patients via microcomputer. Off-line spectral analysis of the waveform database revealed four main classes to transfer function: those with an overall flat transfer function (curve type 1); those with an elevated low-frequency response (curve type 2); those with an elevated high-frequency response (curve type 3); and those exhibiting both an elevated low- and high-frequency response (curve type 4). Curve types 2 and 4 were most often associated with raised ICP (> 20 mm Hg), whereas curve types 1 and 3 were often affiliated with ICP less than 15 mm Hg. Studies of this type may provide insight into the pathophysiology of the CVB and ultimately aid in the prediction and treatment of raised ICP.
引用
收藏
页码:871 / 880
页数:10
相关论文
共 29 条
[1]   MEASUREMENT OF ARTERIAL-PRESSURE USING CATHETER TRANSDUCER SYSTEMS - IMPROVEMENT USING THE ACCUDYNAMIC [J].
ALLAN, MWB ;
GRAY, WM ;
ASBURY, AJ .
BRITISH JOURNAL OF ANAESTHESIA, 1988, 60 (04) :413-418
[2]  
[Anonymous], 2007, NUMERICAL RECIPES AR
[3]   CEREBROSPINAL-FLUID PULSE PRESSURE AND INTRACRANIAL VOLUME-PRESSURE RELATIONSHIPS [J].
AVEZAAT, CJJ ;
VANEIJNDHOVEN, JHM ;
WYPER, DJ .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1979, 42 (08) :687-700
[4]  
BRAY RS, 1986, INTRACRANIAL PRESSUR, V6, P260
[5]   ANALYSIS OF THE CEREBROSPINAL-FLUID PULSE-WAVE IN INTRACRANIAL-PRESSURE [J].
CARDOSO, ER ;
ROWAN, JO ;
GALBRAITH, S .
JOURNAL OF NEUROSURGERY, 1983, 59 (05) :817-821
[6]   SYSTEMS-ANALYSIS OF INTRA-CRANICAL PRESSURE - COMPARISON WITH VOLUME-PRESSURE TEST AND CSF-PULSE AMPLITUDE ANALYSIS [J].
CHOPP, M ;
PORTNOY, HD .
JOURNAL OF NEUROSURGERY, 1980, 53 (04) :516-527
[7]   AN ALGORITHM FOR MACHINE CALCULATION OF COMPLEX FOURIER SERIES [J].
COOLEY, JW ;
TUKEY, JW .
MATHEMATICS OF COMPUTATION, 1965, 19 (90) :297-&
[8]  
DEARDEN NM, 1986, BRIT J HOSP MED, V36, P94
[9]  
GABE IT, 1972, CARDIOVASCULAR FLUID, P11
[10]  
HANSEN AT, 1950, ACTA PHYSIOL SCAND, V19, P306