A COMPARISON OF CONVENTIONAL AND SPIRAL CT - AN EXPERIMENTAL-STUDY ON THE DETECTION OF SPHERICAL LESIONS

被引:179
作者
KALENDER, WA
POLACIN, A
SUSS, C
机构
[1] Siemens Medical Systems, Erlangen, 91052
关键词
IMAGE QUALITY; COMPUTED TOMOGRAPHY; PHYSICS AND INSTRUMENTATION; SPIRAL;
D O I
10.1097/00004728-199403000-00001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: It is accepted that spiral CT scanning may offer significant advantages in a number of clinical applications. There is still some concern with respect to image quality, however, since slice sensitivity profiles are slightly broadened due to the table motion. We carried out theoretical analysis, phantom measurements, and computer simulations to evaluate and to compare contrast and spatial resolution for conventional and for spiral scanning. Special emphasis was put on the task of detecting spherical lesions. Materials and Methods: For standard test objects that measure only resolution in the scan plane, no significant difference between conventional and spiral scanning was observed. We therefore designed a phantom setup that allowed us to place spheres of arbitrary diameter and contrast in arbitrary positions to test three-dimensional (3D) resolution. Results: For conventional CT, both lesion contrast and the degree of spatial separation of lesions observed depend on the relation of the start position of the scan series to the random location of a sphere or lesion. Spiral CT offers space-invariant resolution due to its continuous scanning. Small lesion contrast may be improved by up to a factor of 1.8 when compared with conventional CT since slices can be centered retrospectively. Measurements and simulations were in excellent agreement. Conclusion: We conclude that spiral CT can offer improved 3D contrast and spatial resolution. To exploit these advantages, images should be reconstructed in spiral CT at increments of less than half the distance traveled during one 360 degrees tube rotation. With four to five images per such interval, usually equal to the slice width, results very close to the theoretical optimum are achieved. Many of the presented considerations and results apply to other slice imaging modalities like MRI in an analogous fashion.
引用
收藏
页码:167 / 176
页数:10
相关论文
共 31 条
  • [1] SPIRAL CT - DECREASED SPATIAL-RESOLUTION INVIVO DUE TO BROADENING OF SECTION-SENSITIVITY PROFILE
    BRINK, JA
    HEIKEN, JP
    BALFE, DM
    SAGEL, SS
    DICROCE, J
    VANNIER, MW
    [J]. RADIOLOGY, 1992, 185 (02) : 469 - 474
  • [2] BRUBIN GD, 1993, RADIOLOGY, V186, P147
  • [3] PULMONARY NODULE - EVALUATION WITH SPIRAL VOLUMETRIC CT
    COSTELLO, P
    ANDERSON, W
    BLUME, D
    [J]. RADIOLOGY, 1991, 179 (03) : 875 - 876
  • [4] SPIRAL CT OF THE THORAX WITH REDUCED VOLUME OF CONTRAST MATERIAL - A COMPARATIVE-STUDY
    COSTELLO, P
    DUPUY, DE
    ECKER, CP
    TELLO, R
    [J]. RADIOLOGY, 1992, 183 (03) : 663 - 666
  • [5] COMPUTED-TOMOGRAPHY SCANNING WITH SIMULTANEOUS PATIENT TRANSLATION
    CRAWFORD, CR
    KING, KF
    [J]. MEDICAL PHYSICS, 1990, 17 (06) : 967 - 982
  • [6] FELSENBERG D, 1990, FORTSCHR RONTG NEUEN, V153, P516
  • [7] SPIRAL CT OF THE PANCREAS WITH MULTIPLANAR DISPLAY
    FISHMAN, EK
    WYATT, SH
    NEY, DR
    KUHLMAN, JE
    SIEGELMAN, SS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (06) : 1209 - 1215
  • [8] Gmeinwieser J, 1991, Rontgenpraxis, V44, P2
  • [9] HEYWANGKOEBRUNNER SH, 1992, RADIOLOGY, V185, P131
  • [10] HIRSCHFELDER H, 1992, ADV CT 2, P63