MR EXAMINATION OF THE KNEE - INTERPRETATION WITH MULTISCREEN DIGITAL WORKSTATION VS HARD-COPY FORMAT

被引:15
作者
BROWN, JJ
MALCHOW, SC
TOTTY, WG
WILSON, AJ
LEE, JKT
VANNIER, MW
JOST, RG
机构
[1] Mallinckrodt Inst. Radiology, Washington Univ. Sch. of Med., St. Louis, MO 63110
关键词
D O I
10.2214/ajr.157.1.2048543
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A multiscreen imaging workstation was compared with conventional hardcopy format for diagnostic interpretation of MR images of the knee. MR examinations from 30 patients were interpreted by two observers using film displayed both on a standard film panel alternator and an eight-screen digital workstation. Arthroscopic examination of these patients disclosed 30 meniscal tears and five anterior cruciate ligament tears in 28 patients. Two patients had normal arthroscopic examinations. The MR examinations were evaluated with a five-point confidence rating scale. Results were correlated with arthroscopic findings, and receiver-operating-characteristic curves were generated from these data. No significant difference was found between the areas under the receiver-operating-characteristic curves for film and digital display. The time required for image interpretation was greater when using the digital workstation than when using the film by a factor of approximately 2.7. Our data indicate that a multiscreen digital workstation can be used for interpreting MR examinations of the knee without impairment of diagnostic performance, but with increased time required for image interpretation when compared with radiographic film and a film panel alternator.
引用
收藏
页码:81 / 85
页数:5
相关论文
共 26 条
[1]   THE DIGITAL IMAGING WORKSTATION [J].
ARENSON, RL ;
CHAKRABORTY, DP ;
SESHADRI, SB ;
KUNDEL, HL .
RADIOLOGY, 1990, 176 (02) :303-315
[2]   A COMPARISON OF DUAL-ENERGY DIGITAL RADIOGRAPHY AND SCREEN-FILM IMAGING IN THE DETECTION OF SUBTLE INTERSTITIAL PULMONARY-DISEASE [J].
BARNES, GT ;
SABBAGH, EA ;
CHAKRABORTY, DP ;
NATH, PH ;
LUNA, RF ;
SANDERS, C ;
FRASER, RG .
INVESTIGATIVE RADIOLOGY, 1989, 24 (08) :585-591
[3]   DIGITAL AND CONVENTIONAL CHEST IMAGING - A MODIFIED ROC STUDY OF OBSERVER PERFORMANCE USING SIMULATED NODULES [J].
CHAKRABORTY, DP ;
BREATNACH, ES ;
YESTER, MV ;
SOTO, B ;
BARNES, GT ;
FRASER, RG .
RADIOLOGY, 1986, 158 (01) :35-39
[4]   DIGITAL MAMMOGRAPHY - ROC STUDIES OF THE EFFECTS OF PIXEL SIZE AND UNSHARP-MASK FILTERING ON THE DETECTION OF SUBTLE MICROCALCIFICATIONS [J].
CHAN, HP ;
VYBORNY, CJ ;
MACMAHON, H ;
METZ, CE ;
DOI, K ;
SICKLES, EA .
INVESTIGATIVE RADIOLOGY, 1987, 22 (07) :581-589
[5]   MAXIMUM-LIKELIHOOD ESTIMATION OF PARAMETERS OF SIGNAL-DETECTION THEORY AND DETERMINATION OF CONFIDENCE INTERVALS - RATING-METHOD DATA [J].
DORFMAN, DD ;
ALF, E .
JOURNAL OF MATHEMATICAL PSYCHOLOGY, 1969, 6 (03) :487-&
[6]   EXCRETORY UROGRAPHY USING COMPUTED RADIOGRAPHY [J].
FAJARDO, LL ;
HILLMAN, BJ ;
HUNTER, TB ;
CLAYPOOL, HR ;
WESTERMAN, BR ;
MOCKBEE, B .
RADIOLOGY, 1987, 162 (02) :345-351
[7]   THE EFFECT OF VARYING SPATIAL-RESOLUTION ON THE DETECTABILITY OF DIFFUSE PULMONARY NODULES - ASSESSMENT WITH DIGITIZED CONVENTIONAL RADIOGRAPHS [J].
FOLEY, WD ;
WILSON, CR ;
KEYES, GS ;
DIBIANCA, FA ;
SCANLON, GT ;
SCHLEUTER, D ;
LAWSON, TL .
RADIOLOGY, 1981, 141 (01) :25-31
[8]   DIGITAL AND CONVENTIONAL CHEST IMAGES - OBSERVER PERFORMANCE WITH FILM DIGITAL RADIOGRAPHY SYSTEM [J].
GOODMAN, LR ;
FOLEY, WD ;
WILSON, CR ;
RIMM, AA ;
LAWSON, TL .
RADIOLOGY, 1986, 158 (01) :27-33
[9]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[10]   COMPARISON OF 2048-LINE DIGITAL-DISPLAY FORMATS AND CONVENTIONAL RADIOGRAPHS - AN ROC STUDY [J].
HAYRAPETIAN, A ;
ABERLE, DR ;
HUANG, HK ;
FISKE, R ;
MORIOKA, C ;
VALENTINO, D ;
BOECHAT, MI .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (05) :1113-1118