DEVELOPMENT OF THE ACTIVITIES OF DAILY VISION SCALE - A MEASURE OF VISUAL FUNCTIONAL STATUS

被引:423
作者
MANGIONE, CM
PHILLIPS, RS
SEDDON, JM
LAWRENCE, MG
COOK, EF
DAILEY, R
GOLDMAN, L
机构
[1] BETH ISRAEL HOSP,DEPT MED,DIV CLIN EPIDEMIOL,BOSTON,MA 02215
[2] BETH ISRAEL HOSP,DEPT MED,DIV GEN MED,BOSTON,MA 02215
[3] HARVARD UNIV,MASSACHUSETTS EYE & EAR INFIRM,SCH MED,DEPT MAT SCI,HLTH UNIT,BOSTON,MA 02114
[4] HARVARD UNIV,MASSACHUSETTS EYE & EAR INFIRM,SCH MED,DEPT MAT SCI,GEN EYE SERV,BOSTON,MA 02114
[5] HARVARD UNIV,SCH PUBL HLTH,DEPT EPIDEMIOL,BOSTON,MA 02115
关键词
ACTIVITIES OF DAILY VISION SCALE;
D O I
10.1097/00005650-199212000-00004
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
To develop a method for the evaluation of visual function in subjects with cataracts, the authors identified 20 visual activities and categorized them into five subscales (distance vision, near vision, glare disability, night driving, and daytime driving) that comprised the Activities of Daily Vision Scale (ADVS). Each subscale in the ADVS was scored between 100 (no visual difficulty) and 0 (inability to perform the activity because of visual difficulty). In 334 subjects scheduled for cataract extraction (mean age 75 +/- 9 years, 67% women), ADVS scores (mean +/- standard deviation) for each subscale ranged from 44 +/- 31 for night driving to 72 +/- 24 for near vision activities. When administered by telephone, inter-rater reliability coefficients (r) were 0.82 to 0.97 W < 0.001) for each of the subscales, and test-retest reliability was 0.87 for the scale overall. Cronbach's coefficient a was very high for both the in-person (alpha = -0.94) and telephone (alpha = 0.91) formats. Criterion validity, the correlation between visual loss and ADVS score, was 0.37 (P < 0.001) when the ADVS was administered in person and -0.39 (P < 0.001) when it was administered by telephone. Content validity as assessed with factor analysis showed that 88% of the variance of the principal components weighted on one factor. The authors conclude that substantial visual disability is not captured by routine visual testing and that the ADVS is a reliable and valid measure of patient's perception of visual functional impairment.
引用
收藏
页码:1111 / 1126
页数:16
相关论文
共 17 条
[1]
*AM MED ASS COMM R, 1977, PHYS DESK REF OPHTH, pCH8
[2]
APPLEGATE WB, 1987, JAMA-J AM MED ASSOC, V257, P1064
[3]
BERNTHPETERSEN P, 1981, ACTA OPHTHALMOL, V59, P50
[4]
CINCOTTI A, 1979, OPHTHALMOL SURG, V10, P25
[5]
FRAMINGHAM EYE STUDY .1. OUTLINE AND MAJOR PREVALENCE FINDINGS [J].
KAHN, HA ;
LEIBOWITZ, HM ;
GANLEY, JP ;
KINI, MM ;
COLTON, T ;
NICKERSON, RS ;
DAWBER, TR .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1977, 106 (01) :17-32
[6]
CATARACTS AND CATARACT OPERATIONS .2. [J].
LIESEGANG, TJ .
MAYO CLINIC PROCEEDINGS, 1984, 59 (09) :622-632
[7]
LIESEGANG TJ, 1984, MAYO CLIN P, V59, P55
[8]
Nunnally J.C., 1978, PSYCHOMETRIC THEORY, P245
[9]
GENERIC AND DISEASE-SPECIFIC MEASURES IN ASSESSING HEALTH-STATUS AND QUALITY OF LIFE [J].
PATRICK, DL ;
DEYO, RA .
MEDICAL CARE, 1989, 27 (03) :S217-S232
[10]
GLARE TESTING IN CATARACT PATIENTS - INSTRUMENT EVALUATION AND IDENTIFICATION OF SOURCES OF METHODOLOGICAL ERROR [J].
PRAGER, TC ;
URSO, RG ;
HOLLADAY, JT ;
STEWART, RH .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1989, 15 (02) :149-157