HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPHY WITH A PROTOTYPE CAMERA BASED ON SOLID-STATE SCINTILLATION DETECTORS

被引:29
作者
LECOMTE, R
CADORETTE, J
JOUAN, A
HEON, M
ROULEAU, D
GAUTHIER, G
机构
[1] Department of Nuclear Medicine and Radiobiology, University of Sherbrooke, Sherbrooke
基金
英国医学研究理事会;
关键词
D O I
10.1109/23.106719
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The prototype of a high resolution PET camera consisting of two opposite arrays of detectors with independent solid state readout was built and tested. The basic detector unit is the RCA C30994 detector module consisting of two 3×5×20 mm BGO scintillators, each coupled to one silicon avalanche photodiode. The two-dimensional stacking capability of the module allows a high resolution multi-ring detection system to be assembled without crystal coding. The prototype was used to simulate a 31 cm diameter dual ring tomograph suitable for animal studies. Coincident detector pair resolution was measured and the contributions to resolution loss estimated using a platinum sheathed.75 mm 68Ge line source. The intrinsic resolution is 1.9 mm FWHM, 3.5 mm FWTM at the center of the field. The reconstructed point spread function resolution in a stationary mode is 2.3 mm FWHM at the center and 3.1 mm FWHM (tangential), 3.9 mm FWHM (radial) at 5 cm from the center. The axial resolution is less than 3.5 mm FWHM throughout the field. The ring sensitivity for an animal system is 67 Kcps/mCi in air for an axial line source and 3.3 Kcps/µCi/ml for a 10 cm diameter cylinder of 22Na solution. Copyright © 1990 by The Institute of Electrical and Electronics Engineers, Inc.
引用
收藏
页码:805 / 811
页数:7
相关论文
共 11 条
[1]  
BRACEWELL R, 1965, FOURIER TRANSFORM IT, P154
[2]   AN EVALUATION OF A TWO-DIMENSIONAL ARRAY DETECTOR FOR HIGH-RESOLUTION PET [J].
DAHLBOM, M ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (04) :264-272
[3]   INITIAL RESULTS FROM THE DONNER-600 CRYSTAL POSITRON TOMOGRAPH [J].
DERENZO, SE ;
HUESMAN, RH ;
CAHOON, JL ;
GEYER, A ;
UBER, D ;
VULETICH, T ;
BUDINGER, TF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) :321-325
[4]   STATUS OF BGO-AVALANCHE PHOTODIODE DETECTORS FOR SPECTROSCOPIC AND TIMING MEASUREMENTS [J].
LECOMTE, R ;
MARTEL, C ;
CARRIER, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 278 (02) :585-597
[5]  
LECOMTE R, 1985, IEEE T NUCL SCI, V32, P482, DOI 10.1109/TNS.1985.4336878
[6]   GEOMETRY STUDY OF A HIGH-RESOLUTION PET DETECTION SYSTEM USING SMALL DETECTORS [J].
LECOMTE, R ;
SCHMITT, D ;
LAMOUREUX, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) :556-561
[7]  
LECOMTE R, UNPUB IEEE T MED IMA
[8]   A BISMUTH GERMANATE-AVALANCHE PHOTODIODE MODULE DESIGNED FOR USE IN HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPHY [J].
LIGHTSTONE, AW ;
MCINTYRE, RJ ;
LECOMTE, R ;
SCHMITT, D .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :456-459
[9]   SCINTILLATION DETECTION WITH LARGE-AREA REACH-THROUGH AVALANCHE PHOTODIODES [J].
PETRILLO, GA ;
MCINTYRE, RJ ;
LECOMTE, R ;
LAMOUREUX, G ;
SCHMITT, D .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) :417-423
[10]  
SCHMITT D, 1986, J NUCL MED, V27, P99