ENHANCED DETECTION OF HIV-1 SEQUENCES USING POLYMERASE CHAIN-REACTION AND A LIQUID HYBRIDIZATION TECHNIQUE - APPLICATION FOR INDIVIDUALS WITH QUESTIONABLE HIV-1 INFECTION
被引:27
作者:
BRUISTEN, SM
论文数: 0引用数: 0
h-index: 0
机构:NETHERLANDS RED CROSS,BLOOD TRANSFUS SERV,CENT LAB,DEPT DEV RES,POB 9406,1006 AK AMSTERDAM,NETHERLANDS
BRUISTEN, SM
KOPPELMAN, MHGM
论文数: 0引用数: 0
h-index: 0
机构:NETHERLANDS RED CROSS,BLOOD TRANSFUS SERV,CENT LAB,DEPT DEV RES,POB 9406,1006 AK AMSTERDAM,NETHERLANDS
KOPPELMAN, MHGM
VANDERPOEL, CL
论文数: 0引用数: 0
h-index: 0
机构:NETHERLANDS RED CROSS,BLOOD TRANSFUS SERV,CENT LAB,DEPT DEV RES,POB 9406,1006 AK AMSTERDAM,NETHERLANDS
VANDERPOEL, CL
HUISMAN, JG
论文数: 0引用数: 0
h-index: 0
机构:NETHERLANDS RED CROSS,BLOOD TRANSFUS SERV,CENT LAB,DEPT DEV RES,POB 9406,1006 AK AMSTERDAM,NETHERLANDS
HUISMAN, JG
机构:
[1] NETHERLANDS RED CROSS,BLOOD TRANSFUS SERV,CENT LAB,DEPT DEV RES,POB 9406,1006 AK AMSTERDAM,NETHERLANDS
In this report we describe a sensitive HIV-1 detection method which is applicable for confirmation testing of donors whose blood sample gives indeterminate viral-serology results. The method involves performing a polymerase chain reaction (PCR) and detecting the generated fragments using liquid hybridization and gel retardation. We found that it is as specific as blotting on a filter and hybridization with an internal probe but at least tenfold more sensitive. After applying it on DNA samples of a panel of 11 persistent indeterminate anti-p24gag-reactive donors, none was found to be PCR positive. Considering other negative virological and biochemical test results and case-historical data, these donors are not likely to be HIV-1 infected.