ASSESSMENT OF INSERTION TECHNIQUES AND COMPLICATION RATES OF DUAL LUMEN CENTRAL VENOUS CATHETERS IN PATIENTS WITH HEMATOLOGICAL MALIGNANCIES

被引:8
作者
JANSEN, RFM
WIGGERS, T
VANGEEL, BN
VANPUTTEN, WLJ
机构
[1] DR DANIEL DENHOED CANC CTR, DEPT SURG ONCOL, POB 5201, 3008 AE ROTTERDAM, NETHERLANDS
[2] DR DANIEL DENHOED CANC CTR, DEPT STATS, 3008 AE ROTTERDAM, NETHERLANDS
关键词
D O I
10.1007/BF01670555
中图分类号
R61 [外科手术学];
学科分类号
摘要
One hundred and twenty-three dual lumen silicone rubber central venous catheters were inserted into 101 patients with hematological malignancies undergoing intensive treatment. There was a perioperative complication rate of 13%. Open and closed techniques for inserting the catheter were compared. The operating time needed for introducing the catheter by the closed technique (average, 51 minutes) was significantly shorter (p< 0.001) than the time needed for the open technique (70 minutes), whereas complication rates were equal in both techniques. On average, the catheters functioned for 149 days. Complications leading to removal were observed in 29.3% of patients, most of which were catheter-related infections (20.4%). Thromboembolic complications leading to removal were less frequent (4.1%) and appeared significantly earlier (p<0.001). These data indicate that introduction of the catheter by direct puncture of the subclavian vein is a quick and safe technique, and that this type of catheter is suitable for long-term use, both for infusion and for blood sampling. © 1990 Société Internationale de Chirurgie.
引用
收藏
页码:101 / 106
页数:6
相关论文
共 28 条
[1]  
AKER SN, 1982, EXP HEMATOL, V10, P732
[2]  
BODEY GP, 1978, CANCER, V41, P1610, DOI 10.1002/1097-0142(197804)41:4<1610::AID-CNCR2820410452>3.0.CO
[3]  
2-B
[4]  
BOZZETTI F, 1982, SURGERY, V91, P383
[5]  
DAVIS SJ, 1984, AM SURGEON, V50, P673
[6]  
DEJONG PCM, 1985, ACTA ANAESTH SCAND, V29, P48
[7]   THROMBOEMBOLIC COMPLICATIONS FROM CENTRAL VENOUS CATHETERS - A COMPARISON OF 3 CATHETER MATERIALS [J].
EFSING, HO ;
LINDBLAD, B ;
MARK, J ;
WOLFF, T .
WORLD JOURNAL OF SURGERY, 1983, 7 (03) :419-423
[8]   A TOTALLY IMPLANTED INJECTION PORT SYSTEM FOR BLOOD-SAMPLING AND CHEMOTHERAPY ADMINISTRATION [J].
GYVES, JW ;
ENSMINGER, WD ;
NIEDERHUBER, JE ;
DENT, T ;
WALKER, S ;
GILBERTSON, S ;
COZZI, E ;
SARAN, P .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1984, 251 (19) :2538-2541
[9]  
HAWKINS J, 1982, AM J SURG, V144, P624, DOI 10.1016/0002-9610(82)90538-4
[10]  
HEIMBACH DM, 1976, SURG GYNECOL OBSTET, V143, P634