PERSONNEL DOSIMETER ANGULAR RESPONSE PROPERTIES AND THE ADOPTION OF ICRU REPORT-39 QUANTITIES

被引:4
作者
PILTINGSRUD, HV [1 ]
ROBERSON, PL [1 ]
机构
[1] UNIV MICHIGAN, DEPT RADIAT ONCOL, ANN ARBOR, MI 48109 USA
来源
HEALTH PHYSICS | 1992年 / 62卷 / 05期
关键词
DOSIMETRY; PERSONNEL; PHANTOM; DOSE EQUIVALENT; INTERNATIONAL-COMMISSION-ON-RADIOLOGICAL-PROTECTION;
D O I
10.1097/00004032-199205000-00001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new set of quantities for applied health physics has been proposed by the International Commission on Radiation Units and Measurements with the recommendation that they be based on the ICRU sphere phantom model. The quantities proposed for individual monitoring, which incorporate specific nonisotropic angular response properties, are designed to provide an estimate of an individual's H(E) and are the individual dose equivalent, both superficial [effective dose equivalent, H(s)(d))] and penetrating [penetrating effective dose equivalent, H(p)(d)]. Our study of typical dosimeter wearing practices indicated that there were no consistent locations on or angular orientations of dosimeters to the wearer's body. This demonstrated a difficulty in the practical implementation of personnel dosimeters having an angular response approximating H(p)(d) for a specifically selected point on a body, rather than the traditionally assumed design goal of dosimeters using an isotropic response. It also indicated that it is important for dosimeters using a H(p)(d) response to have an adequate means of mounting the dosimeter to assure the required dosimeter orientation to the body under a wide range of conditions of application. Questions remain as to how the specified ICRU sphere reference phantom (or an approximation thereof) can be used as a practical testing laboratory phantom.
引用
收藏
页码:385 / 394
页数:10
相关论文
共 37 条
[1]  
[Anonymous], 1987, ICRP PUBLICATION, V51
[2]  
BOHM J, 1989, PTB99 FED REP GERM P
[3]  
BOHM J, 1985, PTB95 FED REP GERM P
[4]  
BURLIN TE, 1985, RADIAT PROT DOSIM, V12, P83
[5]  
DENNIS JA, 1988, RADIAT PROT DOSIM, V22, P147
[6]  
DIETZE G, 1989, RADIAT PROT DOSIM, V28, P171
[7]  
GLADHILL RL, 1986, NBS863350
[8]  
GROSSWENDT B, 1985, RADIAT PROT DOSIM, V12, P135
[9]  
GROSSWENDT B, 1988, PTBDOS11E FED REP GE
[10]  
HOFERT M, 1985, TISRP162CF EUR CTR N