CAPABILITY EVALUATION OF A SINOGRAM ERROR-DETECTION AND CORRECTION METHOD IN COMPUTED-TOMOGRAPHY

被引:21
作者
HUANG, SC [1 ]
YU, DC [1 ]
机构
[1] UNIV CALIF LOS ANGELES,SCH MED,NUCL MED LAB,LOS ANGELES,CA 90024
基金
美国国家卫生研究院;
关键词
D O I
10.1109/23.159768
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An iterative method for detecting and correcting errors in sinograms is described and its capability evaluated. The method is based on the use of a reconstruction-reprojection procedure to check the consistency of a sinogram. Adjustments of the sinogram are made iteratively to satisfy gradually the consistency requirement. The effectiveness of the method for detecting and correcting errors due to scanner detector problems is demonstrated with computer simulated data and with real data from positron emission tomography. The potential usefulness of the method for quality control of scanners is discussed.
引用
收藏
页码:1106 / 1110
页数:5
相关论文
共 11 条
[1]   A POSITRON TOMOGRAPH WITH 600-BGO CRYSTALS AND 2.6 MM RESOLUTION [J].
DERENZO, SE ;
HUESMAN, RH ;
CAHOON, JL ;
GEYER, AB ;
MOSES, WW ;
UBER, DC ;
VULETICH, T ;
BUDINGER, TF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :659-664
[2]  
HUANG S C, 1991, Journal of Nuclear Medicine, V32, P996
[3]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .3. EFFECT OF SAMPLING [J].
HUANG, SC ;
HOFFMAN, EJ ;
PHELPS, ME ;
KUHL, DE .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (06) :819-826
[4]  
HUANG SC, 1991, P IEEE ENG MED BIOL, V20, pR30
[5]   PROJECTION SPACE ITERATION RECONSTRUCTION REPROJECTION [J].
KIM, JH ;
KWAK, KY ;
PARK, SB ;
CHO, ZH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1985, 4 (03) :139-143
[6]   ITERATIVE CONVOLUTION BACKPROJECTION ALGORITHMS FOR IMAGE-RECONSTRUCTION FROM LIMITED DATA [J].
MEDOFF, BP ;
BRODY, WR ;
NASSI, M ;
MACOVSKI, A .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1983, 73 (11) :1493-1500
[7]   ITERATIVE RECONSTRUCTION REPROJECTION - AN ALGORITHM FOR LIMITED DATA CARDIAC-COMPUTED TOMOGRAPHY [J].
NASSI, M ;
BRODY, WR ;
MEDOFF, BP ;
MACOVSKI, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1982, 29 (05) :333-341
[8]   ITERATIVE RECONSTRUCTION-REPROJECTION AND THE EXPECTATION-MAXIMIZATION ALGORITHM [J].
OLLINGER, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (01) :94-98
[9]   AN EVALUATION OF 3 ALGORITHMS FOR RECONSTRUCTING IMAGES FROM DATA WITH MISSING PROJECTIONS [J].
OLLINGER, JM ;
KARP, JS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :629-634
[10]   PHYSICAL PERFORMANCE OF THE LATEST GENERATION OF COMMERCIAL POSITRON SCANNER [J].
SPINKS, TJ ;
JONES, T ;
GILARDI, MC ;
HEATHER, JD .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :721-725