URANIUM DETERMINATION BY REMOTE TIME-RESOLVED LASER-INDUCED FLUORESCENCE

被引:27
作者
MOULIN, C
ROUGEAULT, S
HAMON, D
MAUCHIEN, P
机构
[1] CEA SACLAY,LMO,GMP,SPE,DEIN,DTA,F-91191 GIF SUR YVETTE,FRANCE
[2] SERV CHIM BIII,BRUYERES CHATEL,FRANCE
关键词
FLUORESCENCE; OPTRODE; REMOTE SENSING; URANIUM;
D O I
10.1366/0003702934066316
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Uranium measurements taken in a hostile environment are required in the nuclear fuel cycle. Current trends are leading toward development of better sensitivity and rapidity as well as remote measurements. Time-Resolved Laser-Induced Fluorescence (TRLIF) is a very selective and sensitive method that has been widely used for uranium determinations in complex matrices. This technique evolved from analysis in a cell located in a glove box to remote measurements via fiber optics in a shielded cell. The setup of Remote Time-Resolved Laser-Induced Fluorescence (RTRLIF) includes an excitation laser focused in the excitation fiber, with the fluorescence collection fibers concentrically positioned around the excitation fiber at the optrode tip, which dips into the solution; the signal is analyzed by a pulsed intensified multichannel spectrofluorimeter. This analyzer allows for the elimination of the unwanted parasital fluorescence (organic, Raman) by the placement of a gate a few microseconds after the laser pulse. Special care is taken in terms of laser focalization, fiber-optic parameters (numerical aperture, diameter, and arrangement), parasital fluorescence, time delay, and width of the gate. Results obtained with RTRLIF in terms of limits of detection (LOD approximately 10(-10) M) are presented and compared with the results obtained by TRLIF.
引用
收藏
页码:2007 / 2012
页数:6
相关论文
共 27 条
[1]   DIRECT URANIUM TRACE ANALYSIS IN PLUTONIUM SOLUTIONS BY TIME-RESOLVED LASER-INDUCED SPECTROFLUOROMETRY [J].
BERTHOUD, T ;
DECAMBOX, P ;
KIRSCH, B ;
MAUCHIEN, P ;
MOULIN, C .
ANALYTICAL CHEMISTRY, 1988, 60 (13) :1296-1299
[2]   DIRECT DETECTION OF TRACE LEVELS OF URANIUM BY LASER-INDUCED KINETIC PHOSPHORIMETRY [J].
BRINA, R ;
MILLER, AG .
ANALYTICAL CHEMISTRY, 1992, 64 (13) :1413-1418
[3]  
BUSHAW BA, 1984, ANAL CHEM S SERIES, V19, P57
[4]  
CAMPEN W, 1979, MIKROCHIM ACTA, V2, P159
[5]  
CHUDYK W, 1992, 1ST P EUR C OPT CHEM, P38
[6]   DIRECT AND FAST DETERMINATION OF URANIUM IN HUMAN URINE SAMPLES BY LASER-INDUCED TIME-RESOLVED SPECTROFLUOROMETRY [J].
DECAMBOX, P ;
MAUCHIEN, P ;
MOULIN, C .
APPLIED SPECTROSCOPY, 1991, 45 (01) :116-118
[7]  
Demtroder W., 1988, LASER SPECTROSCOPY
[8]  
HIRSCHFELD T, 1984, EPA600784067 LAWR LI
[9]   DETERMINATION OF URANIUM AT ULTRATRACE LEVELS BY TIME-RESOLVED LASER FLUORIMETRY [J].
ISHIBASHI, K ;
SAKAMAKI, S ;
IMASAKA, T ;
ISHIBASHI, N .
ANALYTICA CHIMICA ACTA, 1989, 219 (02) :181-190
[10]  
JIA W-J, 1986, Journal of Radioanalytical and Nuclear Chemistry, V108, P33