EFFECT OF THROMBOPLASTIN AND COAGULOMETER INTERACTION ON THE PRECISION OF THE INTERNATIONAL NORMALIZED RATIO

被引:10
作者
PI, DW
RABOUD, JM
FILBY, C
CARTER, CJ
机构
[1] UNIV BRITISH COLUMBIA,METRO MCNAIR CLIN LABS,VANCOUVER,BC,CANADA
[2] UNIV BRITISH COLUMBIA,DEPT PATHOL & LAB MED,VANCOUVER,BC,CANADA
[3] UNIV BRITISH COLUMBIA,DEPT HLTH CARE & EPIDEMIOL,VANCOUVER,BC,CANADA
关键词
PROTHROMBIN TIME; ANTICOAGULANTS; QUALITY CONTROL;
D O I
10.1136/jcp.48.1.13
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Aims - To examine the magnitude of thromboplastin and coagulometer interactions on the precision of International Normalised Ratio (INR) values when the manufacturers' recommended instrument specific International Sensitivity Index (ISI) values are adopted for the INR calculation. Methods - The variability of INR values obtained from four automated photo-optical coagulometers frequently used in North American laboratories was studied. When used with five commercial thromboplastins of moderate to high sensitivity (ISI values 0.92-1.97), 20 prothrombin time results were generated for each of a population of 98 patients on established warfarin treatment. Results - The mean INR values of the patients ranged from 2.05 to 2.81, depending on which reagent/coagulometer combination was used. Within patient variation increased as the median INR value increased. The mean coefficient of variation of within patient INR values was 10%; the mean coefficient of variation of the prothrombin time results in seconds and prothrombin time ratio were 21 and 18%, respectively. Conclusions - There was considerable bias in the estimated ISI values of the thromboplastins compared with the manufacturers' instrument specific ISI value. Despite this apparent imperfection, our study clearly showed that the INR is preferable to other prothrombin time reporting formats for assessing the degree of anticoagulation for patients on warfarin treatment.
引用
收藏
页码:13 / 17
页数:5
相关论文
共 18 条
[1]   IMPRECISION OF PROTHROMBIN TIME MONITORING OF ORAL ANTICOAGULATION - A SURVEY OF HOSPITAL LABORATORIES [J].
ANSELL, JE .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1992, 98 (02) :237-239
[2]  
BARROW DA, 1991, DADE COAGULATION TEC, V19, P3
[3]  
BECKER DM, 1993, ARCH PATHOL LAB MED, V117, P602
[4]  
BUSSEY HI, 1992, ARCH INTERN MED, V152, P278
[5]  
CHECK WA, 1993, CAP TODAY, V7, P1
[6]   ASSESSMENT OF VALUE OF CALIBRATED LYOPHILIZED PLASMAS TO DETERMINE INTERNATIONAL SENSITIVITY INDEX FOR COAGULOMETERS [J].
CLARKE, K ;
TABERNER, DA ;
THOMSON, JM ;
MORRIS, JA ;
POLLER, L .
JOURNAL OF CLINICAL PATHOLOGY, 1992, 45 (01) :58-60
[7]  
HIRSH J, 1992, CHEST S, V102, P312
[8]  
HOUDIJK WPM, 1988, THR8806 ORG TEKN TEC, P6
[9]   FAILURE OF THE INTERNATIONAL NORMALIZED RATIO TO GENERATE CONSISTENT RESULTS WITHIN A LOCAL MEDICAL COMMUNITY [J].
NG, VL ;
LEVIN, J ;
CORASH, L ;
GOTTFRIED, EL .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1993, 99 (06) :689-694
[10]  
PETERS RHM, 1991, THROMB HAEMOSTASIS, V64, P442