MALFUNCTION OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS PLACED BY A NONTHORACOTOMY APPROACH - FREQUENCY OF MALFUNCTION AND VALUE OF CHEST RADIOGRAPHY IN DETERMINING CAUSE

被引:9
作者
DRUCKER, EA [1 ]
BROOKS, R [1 ]
GARAN, H [1 ]
SWEENEY, MO [1 ]
RUSHKIN, JM [1 ]
MCGOVERN, BA [1 ]
MILLER, SW [1 ]
机构
[1] MASSACHUSETTS GEN HOSP,CARDIAC ARRHYTHMIA SERV,CARDIAC UNIT,BOSTON,MA 02114
关键词
D O I
10.2214/ajr.165.2.7618539
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to determine the frequency of system malfunction in patients with nonthoracotomy implantable cardioverter defibrillators and to assess the role of chest radiography in detecting and determining the cause of malfunction. MATERIALS AND METHODS. The study population consisted of 300 consecutive patients in whom implantable cardioverter defibrillators were implanted using an initial nonthoracotomy approach between September 1990 and October 1994. Transvenous electrodes were placed via the subclavian or cephalic vein under local anesthetic. Intraoperative testing, pulse generator implantation, and, if necessary, subcutaneous patch or extrapericardial patch placement via thoracotomy were done in the operating room under general anesthetic, follow-up consisted of routine device interrogation every 2-3 months and annual chest radiography. Chest radiographs were obtained more often if patients were symptomatic or if results of device interrogation were abnormal. RESULTS. Patients were followed up for a mean +/- SD of 19 +/- 14 months following implantation. Implantable cardioverter-defibrillator malfunction occurred in 17 patients (6%) during the follow-up period. Of these, 12 (71%) had component abnormalities on chest radiographs. Patients with radiographically apparent implantable cardioverter-defibrillator abnormalities presented in two discrete ti me periods after device implantation, early (mean, 35 +/- 14 days) and late (mean, 18 +/- 5 months). CONCLUSION. Malfunction of nonthoracotomy implantable cardioverter-defibrillator systems develops infrequently after device implantation. In most cases, the cause can be identified on chest radiographs.
引用
收藏
页码:275 / 279
页数:5
相关论文
共 10 条
[1]   3-YEAR OUTCOME OF A NONTHORACOTOMY APPROACH TO CARDIOVERTER-DEFIBRILLATOR IMPLANTATION IN 189 CONSECUTIVE PATIENTS [J].
BROOKS, R ;
GARAN, H ;
TORCHIANA, D ;
VLAHAKES, GJ ;
DZIUBAN, S ;
NEWELL, J ;
MCGOVERN, BA ;
RUSKIN, JN .
AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (10) :1011-1015
[2]   DETERMINANTS OF SUCCESSFUL NONTHORACOTOMY CARDIOVERTER-DEFIBRILLATOR IMPLANTATION - EXPERIENCE IN 101 PATIENTS USING 2 DIFFERENT LEAD SYSTEMS [J].
BROOKS, R ;
GARAN, H ;
TORCHIANA, D ;
VLAHAKES, GJ ;
JACKSON, G ;
NEWELL, J ;
MCGOVERN, BA ;
RUSKIN, JN .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (07) :1835-1842
[3]  
BROOKS R, 1994, HURSTS HEART, P847
[4]   CARDIOVERTER-DEFIBRILLATOR SYSTEMS IMPLANTED WITHOUT THORACOTOMY - RADIOGRAPHIC FINDINGS [J].
CHMIELEWSKI, SR ;
ZEGEL, HG ;
GOTTLIEB, C ;
FREIMAN, DB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (05) :943-946
[5]   TRANSVENOUS AND SUBCUTANEOUS IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS - RADIOGRAPHIC ASSESSMENT [J].
DALY, BD ;
CASCADE, PN ;
HUMMEL, JD ;
KALBFLEISCH, S ;
STRICKBERGER, SA ;
LANGBERG, J ;
MORADY, F .
RADIOLOGY, 1994, 191 (01) :273-278
[6]   NONTHORACOTOMY LEAD IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS - NORMAL RADIOGRAPHIC APPEARANCE [J].
DALY, BD ;
HUMMEL, JD ;
LANGBERG, J ;
STRICKBERGER, SA ;
KALBFLEISCH, S ;
MORADY, F ;
CASCADE, PN .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (04) :749-752
[7]  
EAGER G, 1994, AJR, V162, P25
[8]   PINCH-OFF SYNDROME - A COMPLICATION OF IMPLANTABLE SUBCLAVIAN VENOUS ACCESS DEVICES [J].
HINKE, DH ;
ZANDTSTASTNY, DA ;
GOODMAN, LR ;
QUEBBEMAN, EJ ;
KRZYWDA, EA ;
ANDRIS, DA .
RADIOLOGY, 1990, 177 (02) :353-356
[9]   DEFIBRILLATOR TWIDDLERS SYNDROME [J].
ROBINSON, LA ;
WINDLE, JR .
ANNALS OF THORACIC SURGERY, 1994, 58 (01) :247-249
[10]   ABDOMINAL TWIDDLERS SYNDROME [J].
RODAN, BA ;
LOWE, JE ;
CHEN, JTT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1978, 131 (06) :1084-1085