FLAME PHOTOMETRIC DETECTION OF SOME TRANSITION-METALS .1. CALIBRATIONS AND SPECTRA

被引:27
作者
SUN, XY [1 ]
MILLIER, B [1 ]
AUE, WA [1 ]
机构
[1] DALHOUSIE UNIV,DEPT CHEM,HALIFAX B3H 4J3,NS,CANADA
来源
CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE | 1992年 / 70卷 / 04期
关键词
D O I
10.1139/v92-149
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
After gas-chromatographic separation as volatile organometallics, some transition elements were found to respond with analytically relevant sensitivities in the flame photometric detector. Their minimum detectable amounts, in mole of metal per second at an S/N(p-t-p) ratio of 2, were 1 X 10(-14) for nickel and 6 X 10(-13) for rhenium, as well as a less sensitive 2 X 10(-12) for molybdenum and 3 X 10(-12) for cobalt. (When divided by 3.7. these values yield the S/sigma = 3 limit of detection as recommended by IUPAC.) Calibration curves were established for these elements in comparison with transition metals already known to respond in the flame photometric detector. Their chemiluminescent spectra, together with that of chromium, were measured in the detector at analytically (as opposed to spectroscopically) optimized conditions. Atomic lines, molecular bands, and continua were all present. Also, the spectra produced by several types of carbon compounds were recorded for a definition of potential spectral interferences from hydrocarbonaceous sample matrices. The atomic lines and the massive continua displayed by certain metals are discussed in some detail. Atomic lines appear up to a limiting energy level of 3.6 eV above ground state. It is suggested that continua could arise from small, perhaps catalytically active particles. Also discussed, in accordance with a reviewer's request, are the analytical performance of the FPD compared to ICP and MIP sources, and the definition and influence of noise on measured performance criteria.
引用
收藏
页码:1129 / 1142
页数:14
相关论文
共 39 条
[1]  
[Anonymous], 1987, ANALYST, V112, P199
[2]   RESPONSE OF A FILTER-LESS FLAME PHOTOMETRIC DETECTOR TO HETERO-ORGANICS [J].
AUE, WA ;
HASTINGS, CR .
JOURNAL OF CHROMATOGRAPHY, 1973, 87 (01) :232-235
[3]   FLAME PHOTOMETRIC DETECTION OF SOME TRANSITION-METALS .2. ENHANCEMENT OF SELECTIVITY [J].
AUE, WA ;
MILLIER, B ;
SUN, XY .
CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1992, 70 (04) :1143-1155
[4]   DETERMINATION OF (METHYLCYCLOPENTADIENYL)MANGANESE TRICARBONYL IN GASOLINES BY GAS-CHROMATOGRAPHY WITH FLAME PHOTOMETRIC DETECTION [J].
AUE, WA ;
MILLIER, B ;
SUN, XY .
ANALYTICAL CHEMISTRY, 1990, 62 (22) :2453-2457
[5]  
AUE WA, 1990, 73RD CIC C HAL
[8]   FLAME PHOTOMETRIC DETECTOR - APPLICATION OF A SPECIFIC DETECTOR FOR PHOSPHORUS AND FOR SULFUR COMPOUNDS-SENSITIVE TO SUBNANOGRAM QUANTITIES [J].
BRODY, SS ;
CHANEY, JE .
JOURNAL OF GAS CHROMATOGRAPHY, 1966, 4 (02) :42-&
[9]   IMPROVED FLAME PHOTOMETRIC DETECTOR FOR GAS-CHROMATOGRAPHY [J].
BURGETT, CA ;
GREEN, LE .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1975, B 30 (02) :55-60
[10]   EMISSION SPECTRA OBTAINED FROM COMBUSTION OF ORGANIC COMPOUNDS IN HYDROGEN FLAMES [J].
DAGNALL, RM ;
SMITH, DJ ;
THOMPSON, KC ;
WEST, TS .
ANALYST, 1969, 94 (1123) :871-&