AUTOMATED IMAGE CYTOMETRY FOR DETECTION OF RARE, VIRAL ANTIGEN-POSITIVE CELLS IN PERIPHERAL-BLOOD

被引:15
作者
PLOEMZAAIJER, JJ
MESKER, WE
BOLAND, GJ
SLOOS, WCR
VANDERIJKE, FM
JIWA, M
RAAP, AK
机构
[1] FREE UNIV AMSTERDAM,DEPT PATHOL,AMSTERDAM,NETHERLANDS
[2] UNIV UTRECHT HOSP,BLOOD TRANSFUS LAB,UTRECHT,NETHERLANDS
来源
CYTOMETRY | 1994年 / 15卷 / 03期
关键词
IMMUNOCYTOCHEMISTRY; VIRAL INFECTIONS; RARE EVENT DETECTION; AUTOMATED CYTOMETRY; SCREENING;
D O I
10.1002/cyto.990150304
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A cell detection method based upon automated screening is described for recognition of low frequencies (1 in 100,000) of immuno-enzymatically labelled white blood cells in human peripheral blood. The used image cytometry instrumentation (LEYTAS) includes a wide-field, fully automated microscope (Autoplan) and a modular image analysis computer (MIAC), both from Leica, Wetzlar, Germany. The MIAC contains image boards for optimum use of mathematical morphology algorithms. Communication with the MIAC is via a personal computer. Programs for automated cell analysis have been written in C language. Main features of the system are fast analysis of large microscope fields including a count of all cells, selection of objects of interest (alarms), and display of digitally stored images of these alarms, We tested this system for the detection of white blood cells expressing antigen of cytomegalovirus (pp65) in 50 human blood smears from kidney transplant recipients. Immuno-enzymatic (peroxidase) staining was performed with DAB and counterstaining with hematoxylin. For determination of the sensitivity, a series of dilutions of a positive sample with a negative sample was performed. The lowest frequency detected was 1 antigen-positive cell / 3 x 10(5) antigen-negative cells. Screening time was about 60 min for one million cells. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:199 / 206
页数:8
相关论文
共 25 条
[1]  
BARTESL PHS, 1976, AUTOMATION URINE CAN, P268
[2]   FLOW CYTOMETRIC ANALYSIS OF ERYTHROCYTE POPULATIONS IN TN SYNDROME BLOOD USING MONOCLONAL-ANTIBODIES TO GLYCOPHORIN-A AND THE TN-ANTIGEN [J].
BIGBEE, WL ;
LANGLOIS, RG ;
STANKER, LH ;
VANDERLAAN, M ;
JENSEN, RH .
CYTOMETRY, 1990, 11 (02) :261-271
[3]   IMAGE CYTOMETRY OF ESTROGEN-RECEPTORS IN BREAST CARCINOMAS [J].
COHEN, O ;
BRUGAL, G ;
SEIGNEURIN, D ;
DEMONGEOT, J .
CYTOMETRY, 1988, 9 (06) :579-587
[4]  
DENENGELSE P, 1988, CYTOMETRY, V2, P92
[5]   COMPARISON OF DIFFERENT IMMUNOSTAINING TECHNIQUES AND MONOCLONAL-ANTIBODIES TO THE LOWER MATRIX PHOSPHOPROTEIN (PP65) FOR OPTIMAL QUANTITATION OF HUMAN CYTOMEGALOVIRUS ANTIGENEMIA [J].
GERNA, G ;
REVELLO, MG ;
PERCIVALLE, E ;
MORINI, F .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (05) :1232-1237
[6]   DETECTION OF MINIMAL RESIDUAL DISEASE IN ACUTE-LEUKEMIA - POSSIBILITIES AND LIMITATIONS [J].
HAGENBEEK, A ;
MARTENS, ACM .
EUROPEAN JOURNAL OF CANCER & CLINICAL ONCOLOGY, 1985, 21 (03) :389-395
[7]   FETAL CELLS IN THE BLOOD OF PREGNANT-WOMEN - DETECTION AND ENRICHMENT BY FLUORESCENCE-ACTIVATED CELL SORTING [J].
HERZENBERG, LA ;
BIANCHI, DW ;
SCHRODER, J ;
CANN, HM ;
IVERSON, GM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1979, 76 (03) :1453-1455
[8]  
HUSAIN OAN, 1978, ACTA CYTOL, V22, P15
[9]   AN IMPROVED IMMUNOCYTOCHEMICAL METHOD FOR THE DETECTION OF HUMAN CYTOMEGALO-VIRUS ANTIGENS IN PERIPHERAL-BLOOD LEUKOCYTES [J].
JIWA, NM ;
VANDERIJKE, FM ;
MULDER, A ;
VANDERBIJ, W ;
THE, TH ;
ROTHBARTH, PH ;
VELZING, J ;
VANDERPLOEG, M ;
RAAP, AK .
HISTOCHEMISTRY, 1989, 91 (04) :345-349
[10]   MEASUREMENTS OF THE FREQUENCY OF HUMAN-ERYTHROCYTES WITH GENE-EXPRESSION LOSS PHENOTYPES AT THE GLYCOPHORIN-A LOCUS [J].
LANGLOIS, RG ;
BIGBEE, WL ;
JENSEN, RH .
HUMAN GENETICS, 1986, 74 (04) :353-362