INFLUENCE OF OPERATING PARAMETERS ON THE PREPARATIVE GRADIENT ELUTION CHROMATOGRAPHY OF INSULINS

被引:7
作者
COX, GB
机构
[1] Prochrom Inc., Indianapolis, IN 46278
来源
JOURNAL OF CHROMATOGRAPHY | 1992年 / 599卷 / 1-2期
关键词
D O I
10.1016/0021-9673(92)85473-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The mass-overloaded separation of bovine and porcine insulins has been studied in the reversed-phase gradient elution mode. Strong solute-solute displacement effects have been found, which are related to the efficiency of the column used. Low flow-rates and small particle diameters maximise the displacements, as well as improve the resolution between the parent insulin and its desamido contaminant. The gradient slope did not substantially affect the separation between the parent insulins, but, due to the relative "S" values of the solutes, an increase in gradient slope improved the separation of the parent insulin from its desamido compound. An optimum pore size of 150 angstrom was found for the insulins. Experiments to optimise the loadability were not carried out, but a recovery of 90% at a purity of 99.5% was obtained with a loading of 12 mg/g of porcine insulin.
引用
收藏
页码:195 / 203
页数:9
相关论文
共 15 条
[1]  
BOX GB, 1989, J CHROMATOGR, V484, P409
[2]   PREPARATIVE SEPARATION OF PEPTIDE AND PROTEIN SAMPLES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH GRADIENT ELUTION .2. EXPERIMENTAL EXAMPLES COMPARED WITH THEORY [J].
COX, GB ;
ANTLE, PE ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1988, 444 :325-344
[3]   DISPLACEMENT EFFECTS IN PREPARATIVE GRADIENT HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATIONS [J].
COX, GB ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1992, 590 (01) :17-33
[4]  
COX GB, UNPUB
[5]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC PREPARATION OF SINGLE-SITE CARRIER-FREE PANCREATIC-POLYPEPTIDE HORMONE RADIOTRACERS [J].
FRANK, BH ;
BECKAGE, MJ ;
WILLEY, KA .
JOURNAL OF CHROMATOGRAPHY, 1983, 266 (AUG) :239-248
[6]   COMPUTER-SIMULATION OF THE SEPARATION OF A 2-COMPONENT MIXTURE IN PREPARATIVE SCALE LIQUID-CHROMATOGRAPHY [J].
GUIOCHON, G ;
GHODBANE, S .
JOURNAL OF PHYSICAL CHEMISTRY, 1988, 92 (12) :3682-3686
[7]   ADSORPTION-ISOTHERMS ON HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SORBENTS .2. PROTEINS ON CATION EXCHANGERS WITH SILICA SUPPORT [J].
HUANG, JX ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY, 1987, 406 :285-294
[8]  
KNOX JH, 1986, J CHROMATOGR, V363, P1
[9]   PRODUCTION SCALE PURIFICATION OF BIOSYNTHETIC HUMAN INSULIN BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KROEFF, EP ;
OWENS, RA ;
CAMPBELL, EL ;
JOHNSON, RD ;
MARKS, HI .
JOURNAL OF CHROMATOGRAPHY, 1989, 461 :45-61
[10]  
NICOUD RM, 1991, LC GC, V8, P24