DESIGN, FABRICATION, AND IN-VITRO EVALUATION OF AN IN-VIVO ULTRASONIC DOPPLER WALL SHEAR RATE MEASURING DEVICE

被引:11
作者
KEYNTON, RS [1 ]
NEMER, RE [1 ]
NEIFERT, QY [1 ]
FATEMI, RS [1 ]
RITTGERS, SE [1 ]
机构
[1] SUMMA HLTH SYST, VASC HEMODYNAM RES LAB, AKRON, OH 44309 USA
关键词
D O I
10.1109/10.376147
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In vivo wall shear rates have been obtained based on estimates from either volume flow rate or single point velocity measurements along with the wall no slip assumption and a simple linear regression, Recent results [19] have shown that, under pulsatile Bow conditions, wall shear rates are more accurately predicted by using up to four velocity points and a second- or third-order polynomial curve fit, It is the purpose of this paper to evaluate the accuracy of a new, in vivo transducer capable of determining wall shear rates nonintrusively from velocities at three points along a line perpendicular to the vessel wall. Three 20-MHz ultrasound crystals were imbedded in an elastomer at distances of 1.5 and 2.1 mm with beam angles of 30 degrees, 45 degrees, and 60 degrees to the horizontal plane. Microscopic examination showed that intercrystal spacings were within 1.5% of the design and the crystal angles were placed within 2.0%, In vitro calibration was performed under steady and pulsatile flow conditions with average shear rates being within 4.3 +/- 17.3% and 0.2 +/- 0.6%, respectively, of the theoretically predicted values, Furthermore, peak and oscillatory shear rates were within -5.6 +/- 2.2% and -2,4 +/- 5.7% accuracy, respectively, Results from this study show this device to be capable of providing accurate wall shear rates in vivo.
引用
收藏
页码:433 / 441
页数:9
相关论文
共 25 条
[1]   AN EXPERIMENTAL-STUDY OF CORONARY-ARTERY FLUID-MECHANICS [J].
ALTOBELLI, SA ;
NEREM, RM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1985, 107 (01) :16-23
[2]   WALL SHEAR-STRESS RATHER THAN SHEAR RATE REGULATES CYTOPLASMIC CA++ RESPONSES TO FLOW IN VASCULAR ENDOTHELIAL-CELLS [J].
ANDO, J ;
OHTSUKA, A ;
KORENAGA, R ;
KAWAMURA, T ;
KAMIYA, A .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1993, 190 (03) :716-723
[3]  
BARELI SA, 1990, ARTERIOSCLEROSIS, V10, P688
[4]  
BASSIOUNY HS, 1988, SORGICAL FORUM, P328
[5]   PROFILES OF VELOCITY IN CORONARY-ARTERIES OF DOGS INDICATE LOWER SHEAR RATE ALONG INNER ARTERIAL CURVATURE [J].
BELL, DR ;
SABBAH, HN ;
STEIN, PD .
ARTERIOSCLEROSIS, 1989, 9 (02) :167-175
[6]  
BINNS RL, 1989, J VASC SURG, V10, P326
[7]  
CARO CG, 1978, MECHANICS CIRCULATIO
[8]  
DOBRIN PB, 1989, SURG MAR, P393
[9]   DERIVATION OF SHEER RATES FROM NEAR-WALL LDA MEASUREMENTS UNDER STEADY AND PULSATILE FLOW CONDITIONS [J].
FATEMI, RS ;
RITTGERS, SE .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1994, 116 (03) :361-368
[10]   ARTERIAL GEOMETRY AFFECTS HEMODYNAMICS - A POTENTIAL RISK FACTOR FOR ATHEROSCLEROSIS [J].
FRIEDMAN, MH ;
DETERS, OJ ;
MARK, FF ;
BARGERON, CB ;
HUTCHINS, GM .
ATHEROSCLEROSIS, 1983, 46 (02) :225-231