DIRECT INJECTION OF BLOOD-SAMPLES INTO A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ADENINE ANALYZER TO MEASURE ADENINE, ADENOSINE AND THE ADENINE-NUCLEOTIDES WITH FLUORESCENCE DETECTION

被引:25
作者
FUJIMORI, H [1 ]
SASAKI, T [1 ]
HIBI, K [1 ]
SENDA, M [1 ]
YOSHIOKA, M [1 ]
机构
[1] JAPAN SPECTROSCOP CO LTD,HACHIOJI,TOKYO 192,JAPAN
来源
JOURNAL OF CHROMATOGRAPHY | 1990年 / 515卷
关键词
D O I
10.1016/S0021-9673(01)89331-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Adenine (Ade), adenosine (Ado) and its nucleotides such as AMP, cAMP, ADP and ATP in blood or plasma were determined by a high-performance liquid chromatographic (HPLC) adenine analyser with fluorescence detection. In order to inject samples directly into the HPLC system without pretreatment except dilution, the analyser consisted of two systems each, having three columns (pre-, mini- and analytical). A precolumn with an inlet filter of pore size 40 μm was common to both systems and packed with Butyl-Toyopearl 650-M to remove hydrophobic compounds and blood cell membranes. In the system for analysis of the nucleotides, a mini-column of Hitachi anion-exchange gel 3013-N was used for adsorbing AMP, cAMP, ADP and ATP. The adsorbed nucleotides were separated by the Hitachi gel 3013-N analytical column. In the other system for analysis of Ado and Ade, they were adsorbed on a Develosil ODS-5 mini-column and separated by an Asahipak GS-320H size-exclusion analytical column. The adenine compounds in each eluate were derivatized online in a 15-m reaction coil at 115°C with bromoacetaldehyde as the fluorescent reagent in each mobile phase for the analytical column, and detected by spectrofluorimetry. ATP, ADP and AMP were accurately determined by the direct injection of hamster, rat and human whole blood. Authentic Ade and Ado were well separated and Ado in human plasma was determined, but it was difficult to determine it in rat plasma owing to interference from an unknown compound. © 1990.
引用
收藏
页码:363 / 373
页数:11
相关论文
共 29 条
[1]   FLUOROMETRIC ASSAY OF ADENINE AND ITS DERIVATIVES [J].
AVIGAD, G ;
DAMLE, S .
ANALYTICAL BIOCHEMISTRY, 1972, 50 (01) :321-&
[2]   CARDIAC NUCLEOTIDES IN HYPOXIA - POSSIBLE ROLE IN REGULATION OF CORONARY BLOOD FLOW [J].
BERNE, RM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1963, 204 (02) :317-&
[3]   ONLINE SAMPLE PROCESSING AND ANALYSIS OF DIOL COMPOUNDS IN BIOLOGICAL-FLUIDS [J].
BOOS, KS ;
WILMERS, B ;
SCHLIMME, E ;
SAUERBREY, R .
JOURNAL OF CHROMATOGRAPHY, 1988, 456 (01) :93-104
[4]   DETERMINATION OF ADENOSINE IN NORMAL HUMAN-PLASMA AND SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CAPOGROSSI, MC ;
HOLDINESS, MR ;
ISRAILI, ZH .
JOURNAL OF CHROMATOGRAPHY, 1982, 227 (01) :168-173
[5]  
DALY JW, 1979, PHYSL REGULATORY FUN, P229
[6]  
GIBLETT ER, 1972, LANCET, V2, P1067
[7]   EXTRACELLULAR ATP - EFFECTS, SOURCES AND FATE [J].
GORDON, JL .
BIOCHEMICAL JOURNAL, 1986, 233 (02) :309-319
[8]   PERFORMANCE OF MICROPARTICLE CHEMICALLY-BONDED ANION-EXCHANGE RESINS IN ANALYSIS OF NUCLEOTIDES [J].
HARTWICK, RA ;
BROWN, PR .
JOURNAL OF CHROMATOGRAPHY, 1975, 112 (OCT29) :651-662
[9]   DEVELOPMENT AND APPLICATION OF A SIMPLE MICROASSAY FOR ADENOSINE IN RAT PLASMA [J].
JACKSON, EK ;
OHNISHI, A .
HYPERTENSION, 1987, 10 (02) :189-197
[10]  
KALCKAR HM, 1947, J BIOL CHEM, V167, P429