INVIVO AND INVITRO TESTING OF GLOVES FOR PROTECTION AGAINST UV-CURABLE ACRYLATE RESIN SYSTEMS

被引:13
作者
RIETSCHEL, RL
HUGGINS, R
LEVY, N
PRUITT, PM
机构
[1] AT&T TECHNOL INC, NORCROSS, GA 30071 USA
[2] AT&T BELL LABS, NORCROSS, GA 30071 USA
关键词
D O I
10.1111/j.1600-0536.1984.tb01009.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
The permeation of a UV-curable urethane acrylate resin system through glove materials was greatest for latex and neoprene gloves and less for 2 nitrile gloves. Permeation in vitro for the resin system took longer than 480 min. Individual components of the resin permeated faster when tested separately than when in the formulated system. In vivo 48-h patch test data suggested that neither nitrile glove would be adequate for worker protection, but the in vivo test exaggerated the duration of contact between resin, glove and skin. Both nitrile gloves provide adequate protection under use conditions, provided the gloves were not re-used within 8 h. [Workers exposed to a variety of UV-curable acrylates develop allergic contact dermatitis].
引用
收藏
页码:279 / 282
页数:4
相关论文
共 6 条
[1]  
BJOERKNER B, 1980, CONTACT DERMATITIS, V6, P405
[2]   ACRYLATES IN INDUSTRY [J].
CALNAN, CD .
CONTACT DERMATITIS, 1980, 6 (01) :53-54
[3]   2-HYDROXY-ETHYL-METHACRYLATE AND DIETHYLENE AND TETRAETHYLENE GLYCOL DIMETHACRYLATE - CONTACT SENSITIZERS IN A PHOTOPREPOLYMER PRINTING PLATE PROCEDURE [J].
MALTEN, KE ;
BENDE, WJM .
CONTACT DERMATITIS, 1979, 5 (04) :214-220
[4]  
MOURSIDEN HT, 1971, T ST JOHNS HOSP DERM, V59, P230
[5]   CONTACT DERMATITIS FROM PENETRATION OF RUBBER GLOVES BY ACRYLIC MONOMER [J].
PEGUM, JS ;
MEDHURST, FA .
BMJ-BRITISH MEDICAL JOURNAL, 1971, 2 (5754) :141-+
[6]   PERMEABILITY OF LABORATORY GLOVES TO SELECTED SOLVENTS [J].
SANSONE, EB ;
TEWARI, YB .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1978, 39 (02) :169-174