CHIRAL HPLC VERSUS CHIRAL SFC - EVALUATION OF LONG-TERM STABILITY AND SELECTIVITY OF CHIRALCEL OD USING VARIOUS ELUENTS

被引:36
作者
LYNAM, KG
NICOLAS, EC
机构
[1] The Du Pont Merck Pharmaceutical Company, Deepwater
关键词
CHIRAL ANALYSIS; HPLC; SUPERCRITICAL FLUID CHROMATOGRAPHY; CHIRAL STATIONARY PHASE STABILITY; SELECTIVITY;
D O I
10.1016/0731-7085(93)80104-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The long-term stability of Chiralcel OD columns under varying HPLC and SFC conditions was evaluated. Two new columns from the same supplier lot were procured, and one was installed in an HPLC system, and the other was installed in an SFC system. Enantiomeric mixtures of trans-stilbene bride and carbobenzyloxy phenylalaninol were repeatedly injected in both systems over several days. For HPLC, hexane was the primary solvent used, along with IPA, EtOH, MeOH/IPA, or EtOH/TFA modifier. Carbon dioxide was the primary SFC solvent, together with the similar modifiers as the HPLC. Column performance was monitored by measuring resolution, theoretical plate number, and or between enantiomeric peaks. It was observed that, when the eluent strengths were adjusted to provide comparable retention times, the Chiralcel OD gave superior enantiomeric resolution when used in the SFC than the HPLC. Equilibration in between solvents was faster with SFC. The columns were demonstrated to be guile stable in both systems
引用
收藏
页码:1197 / 1206
页数:10
相关论文
共 11 条
[1]   CHIRAL PI-DONOR STATIONARY PHASES WITH (R)-N-PIVALOYLNAPHTHYLETHYLAMIDE GROUPS FOR DIRECT ENANTIOMER SEPARATION BY GAS, LIQUID AND SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
BRUGGER, R ;
KRAHENBUHL, P ;
MARTI, A ;
STRAUB, R ;
ARM, H .
JOURNAL OF CHROMATOGRAPHY, 1991, 557 (1-2) :163-171
[2]   ENANTIOMER RESOLUTION OF D-ALPHA-AMINO AND L-ALPHA-AMINO ACID-DERIVATIVES BY SUPERCRITICAL FLUID CHROMATOGRAPHY ON NOVEL CHIRAL DIAMIDE PHASES WITH CARBON-DIOXIDE [J].
DOBASHI, A ;
DOBASHI, Y ;
ONO, T ;
HARA, S ;
SAITO, M ;
HIGASHIDATE, S ;
YAMAUCHI, Y .
JOURNAL OF CHROMATOGRAPHY, 1989, 461 :121-127
[3]  
GASPARRINI F, 1990, HRC-J HIGH RES CHROM, V13, P182
[4]   CARBON-DIOXIDE SUPERCRITICAL FLUID CHROMATOGRAPHY ON A CHIRAL DIAMIDE STATIONARY PHASE FOR THE RESOLUTION OF D- AND L-AMINO-ACID DERIVATIVES [J].
HARA, S ;
DOBASHI, A ;
KINOSHITA, K ;
HONDO, T ;
SAITO, M ;
SENDA, M .
JOURNAL OF CHROMATOGRAPHY, 1986, 371 :153-158
[5]   LIQUID AND HIGH-PRESSURE CARBON-DIOXIDE CHROMATOGRAPHY OF BETA-BLOCKERS - RESOLUTION OF THE ENANTIOMERS OF NADOLOL [J].
LEE, CR ;
PORZIEMSKY, JP ;
AUBERT, MC ;
KRSTULOVIC, AM .
JOURNAL OF CHROMATOGRAPHY, 1991, 539 (01) :55-69
[6]   CHIRAL RESOLUTIONS IN SFC - MECHANISMS AND APPLICATIONS WITH VARIOUS CHIRAL STATIONARY PHASES [J].
MACAUDIERE, P ;
CAUDE, M ;
ROSSET, R ;
TAMBUTE, A .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1989, 27 (10) :583-591
[7]   RESOLUTION OF ENANTIOMERIC AMIDES ON A PIRKLE-TYPE CHIRAL STATIONARY PHASE - A COMPARISON OF SUBCRITICAL FLUID AND LIQUID-CHROMATOGRAPHIC APPROACHES [J].
MACAUDIERE, P ;
TAMBUTE, A ;
CAUDE, M ;
ROSSET, R ;
ALEMBIK, MA ;
WAINER, IW .
JOURNAL OF CHROMATOGRAPHY, 1986, 371 :177-193
[8]   CO2 SUPERCRITICAL FLUID CHROMATOGRAPHY WITH CHIRAL STATIONARY PHASES - A PROMISING COUPLING FOR THE RESOLUTION OF VARIOUS RACEMATES [J].
MACAUDIERE, P ;
CAUDE, M ;
ROSSET, R ;
TAMBUTE, A .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1989, 27 (07) :383-394
[9]  
RODER W, 1987, HRC-J HIGH RES CHROM, V10, P665
[10]  
SCHURIG V, 1991, J HIGH RES CHROMATOG, V14, P58