TIMING ACCURACY OF MOUSE RESPONSE REGISTRATION ON THE IBM MICROCOMPUTER FAMILY

被引:26
作者
BERINGER, J
机构
[1] Institut für Psychologie, Technische Hochschule Darmstadt, Darmstadt, 6100
来源
BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS | 1992年 / 24卷 / 03期
关键词
D O I
10.3758/BF03203585
中图分类号
B841 [心理学研究方法];
学科分类号
040201 ;
摘要
Data and theoretical estimates reported by Segalowitz and Graves (1990) and Crosbie (1990) regarding delays of serial Microsoft mouse response registration are corrected and extended. Empirically measured mouse responses clearly confirm a theoretical minimum delay time of 22.5 msec for Microsoft-compatible serial mouse devices. Timing accuracy of key actions for the serial, bus, and PS/2 mouse devices are presented.