ONLINE PRECONCENTRATION OF SELENIUM(IV) AND SELENIUM(VI) IN AQUEOUS MATRICES FOLLOWED BY LIQUID CHROMATOGRAPHY INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY DETERMINATION

被引:43
作者
CAI, Y
CABANAS, M
FERNANDEZTURIEL, JL
ABALOS, M
BAYONA, JM
机构
[1] CSIC,CID,DEPT ENVIRONM CHEM,E-08034 BARCELONA,SPAIN
[2] CSIC,INST EARTH SCI JAUME ALMERA,E-08028 BARCELONA,SPAIN
关键词
INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY; LIQUID CHROMATOGRAPHY; PRECONCENTRATION; SELENIUM;
D O I
10.1016/0003-2670(95)00274-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A study was carried out for the determination of selenite and selenate from water matrices using ion-pairing reversed-phase or anion exchange liquid chromatography followed by determination with inductively coupled plasma mass spectrometry (LC-ICP-MS), which used conventional pneumatic nebulization as sample introduction technique. The detection limits and background levels for the anion exchange chromatography were lower than those for the ion-pairing separation method. Based on the optimum conditions obtained with a 25 mu l sample injection loop, a preconcentration column was coupled on-line with the anion exchange LC-ICP-MS system. The capability of this simple on-line preconcentration procedure was demonstrated for the analysis of various water matrices spiked with selenite and selenate including high salt-containing water, river, tap, and well water samples. The detection limits (3 sigma) obtained by preconcentration of 2-10 ml of the high salt-containing water and other aqueous matrices were 0.16-0.42 and 0.08-0.19 mu g l(-1) of Se for selenite and selenate, respectively. These relative detection limits were ca. two orders of magnitude better than those obtained with a 25 mu l sample loop.
引用
收藏
页码:183 / 192
页数:10
相关论文
共 34 条
[1]  
ALBERT M, 1993, ANALUSIS, V21, P403
[2]  
ALVAREZ GH, 1991, ANAL LETT, V24, P1695
[3]  
BROOKS RR, 1983, J ASSOC OFF ANA CHEM, V66, P130
[4]   DETERMINATION OF SELENIUM BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY UTILIZING A NEW HYDRIDE GENERATION SAMPLE INTRODUCTION SYSTEM [J].
BUCKLEY, WT ;
BUDAC, JJ ;
GODFREY, DV ;
KOENIG, KM .
ANALYTICAL CHEMISTRY, 1992, 64 (07) :724-729
[5]   HITACHI ZEEMAN GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETER AS A SELENIUM-SPECIFIC DETECTOR FOR ION CHROMATOGRAPHY - SEPARATION AND DETERMINATION OF SELENITE AND SELENATE [J].
CHAKRABORTI, D ;
HILLMAN, DCJ ;
IRGOLIC, KJ ;
ZINGARO, RA .
JOURNAL OF CHROMATOGRAPHY, 1982, 249 (01) :81-92
[6]   EFFECT OF PHYSICOCHEMICAL PARAMETERS ON TRACE INORGANIC SELENIUM STABILITY [J].
COBO, MG ;
PALACIOS, MA ;
CAMARA, C ;
REIS, F ;
QUEVAUVILLER, P .
ANALYTICA CHIMICA ACTA, 1994, 286 (03) :371-379
[7]  
COLON LA, 1991, HRC-J HIGH RES CHROM, V14, P608
[8]  
D'Ulivo A., 1989, ENV ANAL USING CHROM, P127
[9]   SPECIATION OF BUTYLTIN COMPOUNDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY DETECTION [J].
DAUCHY, X ;
COTTIER, R ;
BATEL, A ;
JEANNOT, R ;
BORSIER, M ;
ASTRUC, A ;
ASTRUC, M .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1993, 31 (10) :416-421
[10]   ANALYTICAL METHODS FOR THE SPECIATION OF SELENIUM-COMPOUNDS - A REVIEW [J].
DAUCHY, X ;
POTINGAUTIER, M ;
ASTRUC, A ;
ASTRUC, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (12) :792-805