THE EFFECT OF SPECIMEN GEOMETRY ON THE MECHANICAL-BEHAVIOR OF TRABECULAR BONE SPECIMENS

被引:188
作者
LINDE, F [1 ]
HVID, I [1 ]
MADSEN, F [1 ]
机构
[1] AARHUS UNIV HOSP,DEPT ORTHOPAED,BIOMECH LAB,DK-8000 AARHUS,DENMARK
关键词
D O I
10.1016/0021-9290(92)90255-Y
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The effect of specimen geometry on the mechanical behaviour of trabecular bone specimens was studied by non-destructive uniaxial compression to 0.4% strain using cylindrical specimens with different sizes and length-to-diameter ratios, and by comparing cubic and cylindrical specimens with the same cross-sectional area. Both the length and the cross-sectional area of the specimen had a highly significant influence on the mechanical behaviour (p < 0.0001). Within the actual range of length (2.75-11.0 mm) the normalized stiffness (Young's modulus) was related nearly linearly to the specimen length. This dependency on specimen length is suggested to be caused mainly by structural disintegrity of the trabecular specimens near the surface. The normalized stiffness (Young's modulus) was also positively correlated to the cross-sectional area. This dependency on cross-sectional area is probably due to friction-induced stress inhomogeneity at the platen-specimen interface. A cube with side length 6.5 mm or a cylindrical specimen with 7.5 mm diameter and 6.5 mm length are suggested as standard specimens for comparative studies on trabecular bone mechanics.
引用
收藏
页码:359 / 368
页数:10
相关论文
共 47 条
  • [1] ANATOMICAL VARIATION OF ORTHOTROPIC ELASTIC-MODULI OF THE PROXIMAL HUMAN TIBIA
    ASHMAN, RB
    RHO, JY
    TURNER, CH
    [J]. JOURNAL OF BIOMECHANICS, 1989, 22 (8-9) : 895 - 900
  • [2] MECHANICAL STRENGTH OF TIBIAL TRABECULAR BONE EVALUATED BY X-RAY COMPUTED-TOMOGRAPHY
    BENTZEN, SM
    HVID, I
    JORGENSEN, J
    [J]. JOURNAL OF BIOMECHANICS, 1987, 20 (08) : 743 - &
  • [3] Brear K, 1988, Eng Med, V17, P163, DOI 10.1243/EMED_JOUR_1988_017_043_02
  • [4] MECHANICAL PROPERTY DISTRIBUTIONS IN THE CANCELLOUS BONE OF THE HUMAN PROXIMAL FEMUR
    BROWN, TD
    FERGUSON, AB
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (03): : 429 - 437
  • [5] COMPRESSIVE BEHAVIOR OF BONE AS A 2-PHASE POROUS STRUCTURE
    CARTER, DR
    HAYES, WC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) : 954 - 962
  • [6] TENSILE FRACTURE OF CANCELLOUS BONE
    CARTER, DR
    SCHWAB, GH
    SPENGLER, DM
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (05): : 733 - 741
  • [7] COOK M, 1945, J I MET, V71, P371
  • [8] Cowin SC., 1989, BONE MECHANICS, P129
  • [9] DIETER GE, 1961, MECHANICAL METALLURG
  • [10] MECHANICAL-BEHAVIOR OF INTRACONDYLAR CANCELLOUS BONE OF FEMUR AT DIFFERENT LOADING RATES
    DUCHEYNE, P
    HEYMANS, L
    MARTENS, M
    AERNOUDT, E
    DEMEESTER, P
    MULIER, JC
    [J]. JOURNAL OF BIOMECHANICS, 1977, 10 (11-1) : 747 - &