FAST CONTINGENCY SCREENING FOR VOLTAGE-REACTIVE CONSIDERATIONS IN SECURITY ANALYSIS

被引:11
作者
HADJSAID, N [1 ]
BENAHMED, M [1 ]
FANDINO, J [1 ]
SABONNADIERE, JC [1 ]
NERIN, G [1 ]
FISCHL, R [1 ]
NWANKPA, CO [1 ]
机构
[1] ELECT FRANCE,DIRECT ETUDES & RECH,DEPT FORCAM,F-92141 CLAMART,FRANCE
关键词
CONTINGENCY ANALYSIS; SPARSE VECTOR; LOCAL SOLUTION; ELECTRICAL DISTANCE; POWER FLOW; DECOUPLED METHOD;
D O I
10.1109/59.221260
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents an efficient contingency screening method for voltage limit violations. The essential points are: 1) The Q-mismatches are calculated exactly for the buses situated in the vicinity of the outaged element and approximatively for the buses that are electrically away from the perturbation. In this step, the convergence rate of individual nodes outside the perturbation area is exploited and the small Q-mismatches are zeroed. 2) It uses the electrical distance concept (1) to predict the buses on which major voltage shifts can occur after the contingency. Computational efforts are saved using the approximate Q-mismatch calculations and by using the sparse vector techniques for the non-zero mismatches (Fast Forward/Back solutions). The number of bus voltages to be solved is drastically reduced and the accuracy of the solution remains good . Results of tests with a 206 buses-299 branches of 400 kV reduced French network are given to illustrate the performance of the method.
引用
收藏
页码:144 / 151
页数:8
相关论文
共 19 条
[1]   REACTIVE POWER CONSIDERATIONS IN AUTOMATIC CONTINGENCY SELECTION [J].
ALBUYEH, F ;
BOSE, A ;
HEATH, B .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (01) :107-112
[2]   SPARSITY-ORIENTED COMPENSATION METHODS FOR MODIFIED NETWORK SOLUTIONS [J].
ALSAC, O ;
STOTT, B ;
TINNEY, WF .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (05) :1050-1060
[3]   FASTER LOCAL-POWER FLOW SOLUTIONS - THE ZERO MISMATCH APPROACH [J].
BACHER, R ;
TINNEY, WF .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1989, 4 (04) :1345-1354
[4]   EFFICIENT BOUNDING METHOD FOR LINEAR CONTINGENCY ANALYSIS [J].
BRANDWAJN, V .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1988, 3 (01) :38-43
[5]   COMPLETE BOUNDING METHOD FOR AC CONTINGENCY SCREENING [J].
BRANDWAJN, V ;
LAUBY, MG .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1989, 4 (02) :724-729
[6]   PRE-SCREENING OF SINGLE CONTINGENCIES CAUSING NETWORK TOPOLOGY CHANGES [J].
BRANDWAJN, V ;
LIU, Y ;
LAUBY, MG .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1991, 6 (01) :30-36
[7]   PARTIAL MATRIX REFACTORIZATION [J].
CHAN, SM ;
BRANDWAJN, V .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1986, 1 (01) :193-200
[8]   DIRECT RANKING FOR VOLTAGE CONTINGENCY SELECTION [J].
CHEN, YL ;
BOSE, AJ .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1989, 4 (04) :1335-1344
[9]   AEP AUTOMATIC CONTINGENCY SELECTOR - BRANCH OUTAGE IMPACTS ON LOAD BUS VOLTAGE PROFILE [J].
DABBAGHCHI, I ;
IRISARRI, G .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1986, 1 (02) :37-45
[10]   FAST CONTINGENCY SCREENING AND EVALUATION FOR VOLTAGE SECURITY ANALYSIS [J].
EJEBE, GC ;
VANMEETEREN, HP ;
WOLLENBERG, BF .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1988, 3 (04) :1582-1590