Numerous studies have revealed frequent false positive septal findings of Tl-201 stress imaging in patients with left bundle branch block (LBBB) even with angiographically excluded significant coronary artery disease (CAD). To scrutinize this phenomenon for stress/rest Tc-99m-methoxyisobutylisonitrile (MIBI) single photon emission computed tomography (SPECT) was used to review 22 patients with constant LBBB. The findings were reversible septal defect in one patient, partially reversible septal defect in one patient and irreversible septal defects in eight patients. In four patients Tc-99m-MIBI scans were entirely normal. Thus, 12/22 (55%) patients revealed normal septal Tc-99m-MIBI uptake. Both patients with a stress-induced septal defect revealed a significant left anterior descending artery stenosis on coronary angiography. These preliminary results suggest, that Tc-99m-MIBI might be more specific and accurate than Tl-201 in the evaluation of CAD in patients with LBBB because of apparently rare or absent false positive septal findings.
引用
收藏
页码:30 / 35
页数:6
相关论文
共 17 条
[1]
Buell U., Dupont F., Uebis R., Kaiser H.J., Kleinhans E., Reske S.N., Hanrath P., 99mTc-methoxy-isobutyl-isonitriIe SPECT to evaluate a perfusion index from regional myocardial uptake after exercise and at rest. Results of a four hour protocol in patients with coronary heart disease and in controls, Nucl Med Commun, 11, pp. 77-94, (1990)
[2]
Rocco T.R., Dilsizian V., Strauss W., Boucher C.A., Technetium-99m isonitrile myocardial uptake at rest. II. Relation to clinical markers of potential viability, J am Coll Cardiol, 14, pp. 1678-1684, (1989)
[3]
Glover D.K., Okada R.D., Myocardial kinetics of Tc-MIBI in canine myocardium after dipyridamole, Circulation, 81, pp. 628-636, (1990)
[4]
Okada R.D., Glover D., Gaffney T., Williams S.W., Myocardial kinetics of technetium-99m-hexakis-2-methoxy-2-methyl-propyl-isonitrile, Circulation, 77, pp. 491-498, (1988)
[5]
Stirner H., Buell U., Kleinhans E., Bares R., Grosse W., Myocardial kinetics of 99m-Tc hexakis-2-methoxy- isobutyl-isonitrile (HMIBI) in patients with coronary heart disease: A comparative study versus 201-T1 with SPECT, Nucl Med Commun, 9, pp. 15-23, (1988)
[6]
Kahn J.K., McGhie I., Akers M.S., Sills M.N., Faber T.L., Kulkarni P.V., Willerson J.T., Corbett J.R., Quantitative rotational tomography with 201 T1 and 99mTc 2-methoxy- isobutyl-isonitrile: A direct comparison in normal individuals and patients with coronary artery disease, Circulation, 79, pp. 1282-1293, (1989)
[7]
Kiat H., Maddahi J., Roy L.T., Van Train T.S., Friedman J., Resser K., Berman D.S., Comparison of Tc-99m methoxy isobutyl isonitrile with thallium-201 for evaluation of coronary artery disease by planar and tomographic methods, Am Heart J, 117, pp. 1-11, (1989)
[8]
Depuey E.G., Guertler-Krawczynska E., Robbins W.L., Thallium-201 SPECT in coronary artery disease patients with left bundle branch block, J Nucl Med, 29, pp. 1479-1485, (1988)
[9]
Hirzel H.O., Senn M., Nuesch K., Buettner C., Pfeiffer A., Hess O.M., Krayenbuehl H.P., Thallium-201 scintigraphy in complete left bundle branch block, Am J Cardiol, 53, pp. 764-769, (1984)
[10]
Knapp W.H., Schmidt U., Bentrup G., Notohamiprodjo G., Gleichmann U., Results of myocardial scintigraphy in patients with left bundle branch block using Tl-201 and Tc- 99m-MIBI, Z Kardiol, 80, pp. 732-737, (1991)