BIODISTRIBUTION AND CLEARANCE OF CONTRAST-CARRYING MREV LIPOSOMES

被引:10
作者
WHITE, C [1 ]
SLIFKIN, M [1 ]
SELTZER, SE [1 ]
BLAU, M [1 ]
ADZAMLI, IK [1 ]
ADAMS, DF [1 ]
机构
[1] HARVARD UNIV,BRIGHAM & WOMENS HOSP,SCH MED,DEPT RADIOL,75 FRANCIS ST,BOSTON,MA 02115
关键词
Computed tomography; Contrast agents; Liposomes;
D O I
10.1097/00004424-199010000-00011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Contrast-carrying liposomes (CCLs) have been shown to increase the attenuation coefficient of the liver and spleen during computed tomographic (CT) imaging. A modification of the reverse-phase evaporation preparative technique (“MREV”) led to production of CCLs that entrap contrast media efficiently. After intravenous injection, MREVs are phagocytized by the Kupffer cells of the liver and the macrophages of the spleen. The biodistribution and clearance of MREVs were studied to evaluate their potential for clinical use, MREVs carrying iodine-125-iotrolan were administered intravenously to 12 rats at doses of 400 mg lipid (containing 400 mg iodine) per kilogram body weight. Pairs of rats were anesthetized and scanned at 3 hours, and 1, 7, 14, 27 and 48 days; CT attenuation values of liver, spleen, blood, kidneys and bladder were measured. Immediately following CT, the rats were killed and tissue specimens were radioassayed. Maximum iodine content in liver and spleen was reached at one day and sustained at high levels for seven days. Biologic removal half-time of the agent in both the liver and spleen was six days. Maximum CT enhancements over baseline were observed at 24 hours and reached 210 Δ HU in the liver and 880 Δ HU in the spleen per gram iodine injected per kilogram body weight. It is concluded that MREVs have appropriate imaging characteristics, biodistribution, and clearance to be effective CT contrast agents. © Lippincott-Raven Publishers.
引用
收藏
页码:1125 / 1129
页数:5
相关论文
共 26 条
[1]  
ADZAMLI IK, IN PRESS INVEST RADI
[2]   CONTRAST ENHANCEMENT OF HEPATIC-TUMORS IN CT - COMPARISON BETWEEN BOLUS AND INFUSION TECHNIQUES [J].
BURGENER, FA ;
HAMLIN, DJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 140 (02) :291-295
[3]   BROMINATED RADIOPAQUE LIPOSOMES - CONTRAST AGENT FOR COMPUTED-TOMOGRAPHY OF LIVER AND SPLEEN - A PRELIMINARY-REPORT [J].
CARIDE, VJ ;
SOSTMAN, HD ;
TWICKLER, J ;
ZACHARIS, H ;
ORPHANOUDAKIS, SC ;
JAFFE, CC .
INVESTIGATIVE RADIOLOGY, 1982, 17 (04) :381-385
[4]   THE PRODUCTION AND EVALUATION OF CONTRAST-CARRYING LIPOSOMES MADE WITH AN AUTOMATIC HIGH-PRESSURE SYSTEM [J].
CHENG, KT ;
SELTZER, SE ;
ADAMS, DF ;
BLAU, M .
INVESTIGATIVE RADIOLOGY, 1987, 22 (01) :47-55
[5]   CONTRAST ENHANCEMENT TECHNIQUE FOR DYNAMIC HEPATIC COMPUTED TOMOGRAPHIC SCANNING [J].
FOLEY, WD ;
BERLAND, LL ;
LAWSON, TL ;
SMITH, DF ;
THORSEN, MK .
RADIOLOGY, 1983, 147 (03) :797-803
[6]   PATTERNS OF CONTRAST ENHANCEMENT OF BENIGN AND MALIGNANT HEPATIC NEOPLASMS DURING BOLUS DYNAMIC AND DELAYED CT [J].
FREENY, PC ;
MARKS, WM .
RADIOLOGY, 1986, 160 (03) :613-618
[7]  
Gregoriadis G, 1988, LIPOSOMES DRUG CARRI, P3
[8]   RADIOPAQUE LIPOSOMES - A PROMISING NEW CONTRAST MATERIAL FOR COMPUTED-TOMOGRAPHY OF THE SPLEEN [J].
HAVRON, A ;
SELTZER, SE ;
DAVIS, MA ;
SHULKIN, P .
RADIOLOGY, 1981, 140 (02) :507-511
[9]   RADIO-OPAQUE LIPOSOMES FOR THE IMPROVED VISUALIZATION OF FOCAL LIVER-DISEASE BY COMPUTERIZED-TOMOGRAPHY [J].
HENZE, A ;
FREISE, J ;
MAGERSTEDT, P ;
MAJEWSKI, A .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1989, 13 (06) :455-462
[10]  
JENDRASIAK GL, 1985, INVEST RADIOL, V9, P995