EFFECTS OF VARIOUS FIXATIVES AND FIXATION CONDITIONS ON DNA PLOIDY ANALYSIS - A NEED FOR STRICT INTERNAL DNA STANDARDS

被引:53
作者
ESTEBAN, JM
SHEIBANI, K
OWENS, M
JOYCE, J
BAILEY, A
BATTIFORA, H
机构
[1] Division of Pathology, City of Hope Nat. Med. Center, Duarte, CA 91010
关键词
DNA PLOIDY; PARAFFIN-EMBEDDED SAMPLES; HISTOGRAM VARIABILITY;
D O I
10.1093/ajcp/95.4.460
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
DNA ploidy and cell cycle analyses are being used with increasing frequency as additional, sometimes independent, biologic prognosticators of various malignancies. For obvious reasons, most of the large studies published are retrospective, using archival paraffin-embedded tissues likely to have been fixed and processed differently. To assess the effect of various fixation conditions on ploidy analyses, the authors performed a comprehensive study in which five contiguous aliquots from 26 tissue samples were fixed in formalin for 8, 24, and 48 hours; B5; and the ethanol-based fixative Omnifix(R) (Omni, Xenetics Biomed Inc., Irvine, CA), respectively. The samples were prepared and stained with the use of Hedley's method; the DNA analyses were done with a Coulter EPICS V(R) flow cytometer (Coulter Electronics, Hialeah, FL); and the resulting histograms were interpreted with Multicycle(R) software (Phoenix Flow Systems, San Diego, CA). Mean channels and coefficients of variation (CVs) of the G0/G1 peaks were compared. Increasing fixation times in formalin produced slight shifting to the left on the G0/G1 peaks with differences up to 13 channels. Omni caused similar but more conspicuous changes, with maximal shifting of 51 channels. B5 created the opposite effect, with right-shifted G0/G1 peaks up to 22 channels. The CVs deteriorated progressively with increasing fixation times in formalin. B5 and Omni fixatives conferred the worse histograms, with 6 and 15 cases, respectively, displaying CVs greater than 8. Such significant differences preclude the use of any other internal standard but adjacent normal tissue that was processed exactly the same as the tumor. The validity of DNA results obtained otherwise should be considered questionable. These findings may explain some of the previously published controversial reports and emphasize the need to use an internal standard and more stringent criteria to define aneuploidy in paraffin-embedded tissue.
引用
收藏
页码:460 / 466
页数:7
相关论文
共 34 条
  • [1] AUTOLYSIS IS A POTENTIAL SOURCE OF FALSE ANEUPLOID PEAKS IN FLOW CYTOMETRIC DNA HISTOGRAMS
    ALANEN, KA
    JOENSUU, H
    KLEMI, PJ
    [J]. CYTOMETRY, 1989, 10 (04): : 417 - 425
  • [2] COMPARISON OF FRESH, ETHANOL-PRESERVED, AND PARAFFIN-EMBEDDED SAMPLES IN DNA FLOW-CYTOMETRY
    ALANEN, KA
    KLEMI, PJ
    JOENSUU, H
    KUJARI, H
    PEKKALA, E
    [J]. CYTOMETRY, 1989, 10 (01): : 81 - 85
  • [3] BAUER KD, 1987, LAB INVEST, V57, P329
  • [4] THE VALUE OF MORPHOMETRY AND DNA FLOW-CYTOMETRY IN ADDITION TO CLASSIC PROGNOSTICATORS IN SUPERFICIAL URINARY-BLADDER CARCINOMA
    BLOMJOUS, ECM
    SCHIPPER, NW
    BAAK, JPA
    VOS, W
    DEVOOGT, HJ
    MEIJER, CJLM
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1989, 91 (03) : 243 - 248
  • [5] COON JS, 1989, CANCER, V63, P1592, DOI 10.1002/1097-0142(19890415)63:8<1592::AID-CNCR2820630825>3.0.CO
  • [6] 2-G
  • [7] DNA PLOIDY AND SURVIVAL IN BREAST-CANCER PATIENTS
    CORNELISSE, CJ
    VANDEVELDE, CJH
    CASPERS, RJC
    MOOLENAAR, AJ
    HERMANS, J
    [J]. CYTOMETRY, 1987, 8 (02): : 225 - 234
  • [8] COULSON PB, 1984, CANCER RES, V44, P4187
  • [9] CRISSMAN JD, 1988, MODERN PATHOL, V1, P198
  • [10] PROGNOSTIC-SIGNIFICANCE OF THE DNA CONTENT OF HUMAN-BREAST CANCER
    DOWLE, CS
    OWAINATI, A
    ROBINS, A
    BURNS, K
    ELLIS, IO
    ELSTON, CW
    BLAMEY, RW
    [J]. BRITISH JOURNAL OF SURGERY, 1987, 74 (02) : 133 - 136