CAPILLARY ELECTROPHORETIC ENZYME-IMMUNOASSAY FOR DIGOXIN IN HUMAN SERUM

被引:40
作者
LIU, XH
XU, Y
IP, MPC
机构
[1] CLEVELAND STATE UNIV, DEPT CHEM, CLEVELAND, OH 44115 USA
[2] METROHLTH MED CTR, DEPT PATHOL, CLEVELAND, OH 44109 USA
关键词
D O I
10.1021/ac00114a017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The combined use of capillary electrophoretic (CE) separation and homogeneous enzyme immunoassay for analyzing drugs in hemolyzed, lipemic, or icteric serum samples was investigated. An FDA-approved EMIT assay kit for digoxin in human serum was used. After the enzyme immunoassay, the enzymatic reaction product (NADH) and remaining substrate (NAD(+)), together with internal standard (p-nitrophenol, NP), were electrokinetically injected into a polyacrylamide-coated electrophoresis capillary and separated under applied potential. Detection was made by monitoring the UV adsorption at wavelength of 260 nm. The digoxin level in human serum was determined by comparing the peak area ratio of NADH and NP to the ratios established by the known digoxin standards. In this study, the factors that influence the CE separation were also investigated. Under the optimum conditions, NADH, NAD(+), and NP were separated at electric field strength of 438 V/cm in the coated capillary (100 mu m x 57 cm) with 200 mM Tris-borate buffer (pH 7.9) containing 0.2% hydroxypropyl methylcellulose, CE analyses of serum samples spiked with NADH standards at concentrations of 100 and 400 mu M resulted in detection variabilities of less than 2% and analytical recoveries of 98-102%. Both an internal calibration plot for NADH and a dose-response curve for digoxin in serum were constructed. Calibrator serum, patients' sera with hemolyzed, lipemic, and icteric interference factors, and other pigmented blood components (e.g., serum albumin, bilirubin, hemoglobin, uric acid, coproporphyrin, melanin, protoporphyrin IX, and uroprophyrin) demonstrated no interference in this method. The authors believed that this method is useful for analyzing digoxin in hemolyzed, lipemic, and icteric blood samples that are known to create problems in conventional EMIT assays and may be applicable to other EMIT-based assays for monitoring drugs in complex biological matrices.
引用
收藏
页码:3211 / 3218
页数:8
相关论文
共 17 条
[1]   INSULIN-I-131 METABOLISM IN HUMAN SUBJECTS - DEMONSTRATION OF INSULIN BINDING GLOBULIN IN THE CIRCULATION OF INSULIN TREATED SUBJECTS [J].
BERSON, SA ;
YALOW, RS ;
BAUMAN, A ;
ROTHSCHILD, MA ;
NEWERLY, K .
JOURNAL OF CLINICAL INVESTIGATION, 1956, 35 (02) :170-190
[2]   CHARACTERIZATION OF PROTEINS BY CAPILLARY ELECTROPHORESIS IN FUSED-SILICA COLUMNS - REVIEW ON SERUM-PROTEIN ANALYSIS AND APPLICATION TO IMMUNOASSAYS [J].
CHEN, FTA ;
STERNBERG, JC .
ELECTROPHORESIS, 1994, 15 (01) :13-21
[3]  
CHEN IW, 1989, CLIN CHEM, P1088
[4]  
EGGERS HM, 1982, CLIN CHEM, V28, P1848
[5]  
HUANG X, 1988, ANAL CHEM, V60, P377
[6]  
KRICKA LJ, 1994, CLIN CHEM, V40, P347
[7]  
MONNIG CA, 1994, ANAL CHEM, V66, pR280, DOI 10.1021/ac00084a013
[8]   SEPARATION OF ANTIBODY-ANTIGEN COMPLEXES BY CAPILLARY ZONE ELECTROPHORESIS, ISOELECTRIC-FOCUSING AND HIGH-PERFORMANCE SIZE-EXCLUSION CHROMATOGRAPHY [J].
NIELSEN, RG ;
RICKARD, EC ;
SANTA, PF ;
SHARKNAS, DA ;
SITTAMPALAM, GS .
JOURNAL OF CHROMATOGRAPHY, 1991, 539 (01) :177-185
[9]  
PETTERSSON K, 1993, CLIN CHEM, V39, P1359
[10]   RAPID IMMUNOASSAYS USING CAPILLARY ELECTROPHORESIS WITH FLUORESCENCE DETECTION [J].
SCHULTZ, NM ;
KENNEDY, RT .
ANALYTICAL CHEMISTRY, 1993, 65 (21) :3161-3165